Question
Chapter 10, Problem 10.2QAP
Interpretation Introduction
Interpretation:
For multi element analysis, the reason for ICP source atomic emission methods to be preferred over flame atomic absorption methods needs to be explained.
Concept introduction:
The temperatures required to excite various elements are different. The process/equipment for each element may, therefore be different and has to be selected for optimum results.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
i) Find the differences between the AES and XPS in terms of principle and information obtained from the spectra.
ii) Why AFM is mostly utilized microscopic method for the determination of the thickness of the film?
Compare the advantages and disadvantages of the inductively coupled plasma and flames in atomic spectroscopy.
6
Why standard solutions are used in Atomic absorption Spectroscopy (AAS) whereas UV-Vis molecular absorbance only extinction coefficient is necessary?
Chapter 10 Solutions
INSTRUMENTAL ANALYSIS-ACCESS >CUSTOM<
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- Induction coupled plasma (ICP) emission spectrometry is widely used for the sensitive multi-element determinations. How does the ICP work?arrow_forwardWhy high-resolution monochromator is needed for atomic emission spectroscopy while atomic absorption spectroscopy requires a monochromator having only low-to-moderate resolving power?arrow_forwardFluorometry is more selective and more sensitive than absorption spectrometry.Tell what is meant by selectivity and sensitivity.arrow_forward
- Explain why the information from an XPS chemical shift must also be contained in an X-ray absorption edge.arrow_forward5arrow_forwardWhich of the following statement is incorrect? The quality of grating of the monochromator affects the resolution of two closely spaced wavelengths in a spectrum. OICP (Inductively coupled plasma) is commonly used in atomic emission spectrometry. Cuvette is generally used for atomic absorption spectrometry (AAS) as the sample cell. The measurement in fluorescence spectrometry is generally more sensitive than absorption spectrometry.arrow_forward
- 1. State the difference between transmittance, absorbance, molar absorptivity, and fluorescence. Which one(s) is proportional to analyte concentration?arrow_forwardExplain the principal work of atomic absorption spectroscopy? And how is it used for the determination of unknown heavy metals and other metals concentrations?arrow_forward3. Explain the main differences between flame atomic absorption spectrophotometry and UV-VIS molecular absorption spectrophotometry in terms of: (a) (b) energy levels and transitions; main instrumental features.arrow_forward
- A company is producing a powder which can be reconstituted as a healthy drink for the elderly. Analysis of the powder for calcium involved using the following procedure. 4 g of powder was reconstituted to 150 ml with water. Thirty ml of 24 % TCA was added to 30 ml of this solution. The mixture was allowed to stand for 15 mins and then filtered. The filtrate was analysed for calcium using atomic absorption spectroscopy. From the standard curve it was found that the reading for the analysed sample was 24mg/litre. Calculate the concentration of calcium in the powder (mg/kg).arrow_forwardWhat percent transmittance range and what absorbance range are considered to be the optimum working ranges for spectrochemical measurements?arrow_forwardExactly 5.00 mL aliquots of a solution containing analyte X were transferred into 50.00-mL volumetric flasks and the pH of the solution is adjusted to 9.0. The following volumes of a standard solution containing 2.00 µg/mL of X were then added into each flask and the mixture was diluted to volume: 0.000, 0.500, 1.00, 1.50 and 2.00 mL. The fluorescence of each of these solutions was measured with a fluorometer, and the following values were obtained: 3.26, 4.80, 6.42, 8.02 and 9.56, respectively. ii. Using relevant functions in Excel, derive a least-squares equation for the data, and use the parameters of this equation to find the concentration of the phenobarbital in the unknown solution.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningChemistry for Engineering StudentsChemistryISBN:9781285199023Author:Lawrence S. Brown, Tom HolmePublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Chemistry for Engineering Students
Chemistry
ISBN:9781285199023
Author:Lawrence S. Brown, Tom Holme
Publisher:Cengage Learning