Question
Chapter 1, Problem 1.4QAP
Interpretation Introduction
Interpretation:
The transducer in smoke detector should be determined.
Concept introduction:
Transducers play a vital role in analysis process. The real physical world data can be converted into a measurable form with the help of these devices. Basically, transducer is a device which convert any form of signal into electrical signals or vice versa. They can either be used at input or output of a system. There are many factors which are considered while selecting a type of transducer to be used for a task. They are sensitivity, range, accuracy, precision, linearity, size and cost.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
"Analytical data are never more reliable than the sampling technique". Explain this statement.
use ion exchange method in analytical separation to separate mercury and nickel from polluted water using analytical steps and protocols.
What is the practical importance of extraction in relation to chemistry especially when it comes to drugs?
Knowledge Booster
Similar questions
- Calcium in a 100.0 mL sample of fuit juice was analyzed by an electrochemical method that gave a detector current of 2.40 mA. A standard addition of 10.00 mL of 80.0mg/mL calcium ion increased the current to 4.56 mA. Find the concentration of calcium in the fruit juice.arrow_forward1. Write a report comparing the principles, limitations/capabilities of the following microscopic techniques. (a) Optical Microscopy(b) Scanning Electron Microscopy(c) Transmission Electron Microscopy(d) Atomic Force Microscopyarrow_forwardPotentially Useful Information Spectrochemical Series: I < Br < SCN < Cl` < NO3¯ < F° < OH° < C2O4² ~ H2O < NCS“ < NH3 < en < PPH3 A student has three test tubes containing a metal (M) nitrate solution M(NO3)2 (aq) (where "M" represents a generic transition metal). The student adds aqueous ammonia (NH3) to one test tube, aqueous hydrochloric acid (HCI) to the second tube, and nothing more to the third tube, but forgets to label the tubes. After this, one test tube contains a red solution, one an orange solution, and one a yellow solution. Note: This metal, M, would follow the same rules that we used for Cu(II), Ni(II), and Co(II). The Jahn-Teller Effect does not apply. Complete each statement or answer each question below about the solutions in the three test tubes. The coordination complex formed by adding HCI to the metal solution has a coordination number of... O 3 2arrow_forward
- A calibration curve constructed from absorbance values of solutions containing a known concentration of permanganate ions has the following best-fit line: y = (3.62 × 103 L/mol) x where y is the absorbance of the solution at 525 nm and x is the concentration of MnO4– (aq) in mol/L. The pathlength of the cuvettes used in the experiment is exactly 1 cm. Using this information, what is the molar absorptivity of MnO4– (aq) at 525 nm?arrow_forwardWhat is the connection of the manhanttan project and chemistry?arrow_forwardExplain the three process of gravimetric analysisarrow_forward
- 31 – 33. An article in Scientific American pointed out that replacing a 75-watt incandescent bulb with an 18-watt compact fluorescent bulb would save about 75% in the cost of electricity. Electricity is generally priced per kilowatt-hour (kWh) and the rate is PhP 10/kW-h. Calculate how much money you would save over the life of one compact fluorescent bulb (about 10,000 h). Note: Standard incandescent bulbs last about 750 h.arrow_forwardA soil sample taken from a hill reveals that soil solution in the top 30 cm of soil contains 900 micromoles Ca/L. Imagine that the grass growing on this hill has a water use efficiency of 400 g H20/g dry matter. Calcium is considered to be sufficient when between 1-2% of the dry matter. Calculate the calcium content in the soil's dry matter and determine if the level is sufficient.arrow_forwardYou have a 11.5 mg sample of blood that contains various proteins. Hemoglobin is the only protein in the sample containing Fe. Hemoglobin contains 3.83% by mass of a compound called heme (C₃₄H₃₂FeN₄O₄, MW = 616.49 g/mol). You find that your 11.5 mg blood sample contains 34.9 micrograms of Fe. What is the mass percent of hemoglobin in your protein sample? -don't prematureley roundarrow_forward
- You have a 11.5 mg sample of blood that contains various proteins. Hemoglobin is the only protein in the sample containing Fe. Hemoglobin contains 3.83% by mass of a compound called heme (C₃₄H₃₂FeN₄O₄, MW = 616.49 g/mol). You find that your 11.5 mg blood sample contains 30.5 micrograms of Fe. What is the mass percent of hemoglobin in your protein sample?arrow_forwardWhat is the importance of calibrating analytical balances?arrow_forwardA medal must contain a minimum of 6 grams of gold (MW = 196.97 g/mol) and at least 92.5% silver. A total of 340 medals were awarded. Suppose each medal is made by coating a 60-mm diameter, 3-mm thick, gold-free silver alloy disk with gold via electrolytic deposition using a gold (III) solution, Determine the following:a) Time required in hours to finish plating all the gold medals with minimum gold content if the available electricity source can deliver 50 amperes of currentarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningChemistry: The Molecular ScienceChemistryISBN:9781285199047Author:John W. Moore, Conrad L. StanitskiPublisher:Cengage Learning
- Chemistry In FocusChemistryISBN:9781305084476Author:Tro, Nivaldo J., Neu, Don.Publisher:Cengage LearningIntroductory Chemistry: A FoundationChemistryISBN:9781337399425Author:Steven S. Zumdahl, Donald J. DeCostePublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Chemistry: The Molecular Science
Chemistry
ISBN:9781285199047
Author:John W. Moore, Conrad L. Stanitski
Publisher:Cengage Learning
Chemistry In Focus
Chemistry
ISBN:9781305084476
Author:Tro, Nivaldo J., Neu, Don.
Publisher:Cengage Learning
Introductory Chemistry: A Foundation
Chemistry
ISBN:9781337399425
Author:Steven S. Zumdahl, Donald J. DeCoste
Publisher:Cengage Learning