Waste gas containing ammonia and sulfur dioxide is treated by water absorption in a single-stage treatment process. The waste gas enters the process at 1 atm pressure and 30°C. The air contains 5.0% v/v ammonia and 7% v/v sulfur dioxide and must leave the with 500,000 ppb ammonia and 400,000 ppb sulfur dioxide. Air, ammonia, and sulfur dioxide can be taken as ideals gases. There is no water and air carryovers in the treated gas and wastewater streams, respectively. If the flow rate of the waste gas to the process is 500 m3/s, calculate the flow- rate of water to the column if the wastewater must contain less than 1% w/w ammonia and less than 2% w/w sulfur dioxide. Treated Gas Water Waste Gas Wastewater

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
Waste gas containing ammonia and sulfur dioxide is treated by water absorption in a single-stage treatment
process. The waste gas enters the process at 1 atm pressure and 30°C. The air contains 5.0% v/v ammonia and 7%
v/v sulfur dioxide and must leave the with 500,000 ppb ammonia and 400,000 ppb sulfur dioxide. Air, ammonia,
and sulfur dioxide can be taken as ideals gases. There is no water and air carryovers in the treated gas and
wastewater streams, respectively. If the flow rate of the waste gas to the process is 500 m3/s, calculate the flow-
rate of water to the column if the wastewater must contain less than 1% w/w ammonia and less than 2% w/w
sulfur dioxide.
Treated Gas
Water
Waste Gas
Wastewater
Transcribed Image Text:Waste gas containing ammonia and sulfur dioxide is treated by water absorption in a single-stage treatment process. The waste gas enters the process at 1 atm pressure and 30°C. The air contains 5.0% v/v ammonia and 7% v/v sulfur dioxide and must leave the with 500,000 ppb ammonia and 400,000 ppb sulfur dioxide. Air, ammonia, and sulfur dioxide can be taken as ideals gases. There is no water and air carryovers in the treated gas and wastewater streams, respectively. If the flow rate of the waste gas to the process is 500 m3/s, calculate the flow- rate of water to the column if the wastewater must contain less than 1% w/w ammonia and less than 2% w/w sulfur dioxide. Treated Gas Water Waste Gas Wastewater
Expert Solution
steps

Step by step

Solved in 4 steps with 1 images

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The