Two generators are connected in parallel to the low voltage side of a transformer. Generators Gl and G 2 are each rated at 50 MVA, 13.8 kV, with a subtransient resistance of 0.2 pu. Transformer T1 is rated at 100 MVA, 13.8/115 kV with a series reactance of 0.08 pu and negligible resistance. Assume that initially the voltage on the high side of the transformer is 120 kV, that the transformer is unloaded, and that there are no circulating currents between the generators. Calculate the subtransient fault current that will flow if a 3 phase fault occurs at the high-voltage side of transformer 美。 AY G, ratings: sÓ MVA G2 ratings: 50 MVA T, ratings: 100 MVA 13.8/11 3AV X - 0.08 pu 13.8 AV 13.8 AV X"- 0.20 pu X"- 0.20 pu
Two generators are connected in parallel to the low voltage side of a transformer. Generators Gl and G 2 are each rated at 50 MVA, 13.8 kV, with a subtransient resistance of 0.2 pu. Transformer T1 is rated at 100 MVA, 13.8/115 kV with a series reactance of 0.08 pu and negligible resistance. Assume that initially the voltage on the high side of the transformer is 120 kV, that the transformer is unloaded, and that there are no circulating currents between the generators. Calculate the subtransient fault current that will flow if a 3 phase fault occurs at the high-voltage side of transformer 美。 AY G, ratings: sÓ MVA G2 ratings: 50 MVA T, ratings: 100 MVA 13.8/11 3AV X - 0.08 pu 13.8 AV 13.8 AV X"- 0.20 pu X"- 0.20 pu
Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
Related questions
Concept explainers
Three-Phase Transformers
Three-segment transformers are a type of transformer used to transform voltages of electrical systems into three ranges. Two type transformers are shell-type transformer and core type transformer. In brief, it could be described because of the exquisite kinds of configurations.
Transformer
Ever since electricity has been created, people have started using it in its entirety. We see many types of Transformers in the neighborhoods. Some are smaller in size and some are very large. They are used according to their requirements. Many of us have seen the electrical transformer but they do not know what work they are engaged in.
Question
![Two generators are connected in parallel to the low voltage side of a
transformer. Generators G1 and G 2 are each rated at 50 MVA, 13.8 kV,
with a subtransient resistance of 0.2 pu. Transformer T1 is rated at 100
MVA, 13.8/115 kV with a series reactance of 0.08 pu and negligible
resistance. Assume that initially the voltage on the high side of the
transformer is 120 kV, that the transformer is unloaded, and that there are
no circulating currents between the generators. Calculate the subtransient
fault current that will flow if a 3 phase fault occurs at the high-voltage
side of transformer
AY
Gz ratings:
50 MVA
G, ratings:
số MVA
13.8 KV
X" = 0.20 pu
T, ratings:
100 MVA
13.8/113 V
X - 0.08 pu
13.8 KV
X" - 0.20 pu
Choose the per-unit base values for this power system to be 100 MVA
and 13.8 kV](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F7829d2b5-1449-40d3-88f1-8d8059871521%2F8383a5d4-01b5-4606-bb44-c565bbe88a51%2Fqmvp44u_processed.jpeg&w=3840&q=75)
Transcribed Image Text:Two generators are connected in parallel to the low voltage side of a
transformer. Generators G1 and G 2 are each rated at 50 MVA, 13.8 kV,
with a subtransient resistance of 0.2 pu. Transformer T1 is rated at 100
MVA, 13.8/115 kV with a series reactance of 0.08 pu and negligible
resistance. Assume that initially the voltage on the high side of the
transformer is 120 kV, that the transformer is unloaded, and that there are
no circulating currents between the generators. Calculate the subtransient
fault current that will flow if a 3 phase fault occurs at the high-voltage
side of transformer
AY
Gz ratings:
50 MVA
G, ratings:
số MVA
13.8 KV
X" = 0.20 pu
T, ratings:
100 MVA
13.8/113 V
X - 0.08 pu
13.8 KV
X" - 0.20 pu
Choose the per-unit base values for this power system to be 100 MVA
and 13.8 kV
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 4 steps with 2 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Introductory Circuit Analysis (13th Edition)](https://www.bartleby.com/isbn_cover_images/9780133923605/9780133923605_smallCoverImage.gif)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
![Delmar's Standard Textbook Of Electricity](https://www.bartleby.com/isbn_cover_images/9781337900348/9781337900348_smallCoverImage.jpg)
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
![Programmable Logic Controllers](https://www.bartleby.com/isbn_cover_images/9780073373843/9780073373843_smallCoverImage.gif)
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
![Introductory Circuit Analysis (13th Edition)](https://www.bartleby.com/isbn_cover_images/9780133923605/9780133923605_smallCoverImage.gif)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
![Delmar's Standard Textbook Of Electricity](https://www.bartleby.com/isbn_cover_images/9781337900348/9781337900348_smallCoverImage.jpg)
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
![Programmable Logic Controllers](https://www.bartleby.com/isbn_cover_images/9780073373843/9780073373843_smallCoverImage.gif)
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
![Fundamentals of Electric Circuits](https://www.bartleby.com/isbn_cover_images/9780078028229/9780078028229_smallCoverImage.gif)
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
![Electric Circuits. (11th Edition)](https://www.bartleby.com/isbn_cover_images/9780134746968/9780134746968_smallCoverImage.gif)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
![Engineering Electromagnetics](https://www.bartleby.com/isbn_cover_images/9780078028151/9780078028151_smallCoverImage.gif)
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,