Two generators are connected in parallel to the low voltage side of a transformer. Generators Gl and G 2 are each rated at 50 MVA, 13.8 kV, with a subtransient resistance of 0.2 pu. Transformer T1 is rated at 100 MVA, 13.8/115 kV with a series reactance of 0.08 pu and negligible resistance. Assume that initially the voltage on the high side of the transformer is 120 kV, that the transformer is unloaded, and that there are no circulating currents between the generators. Calculate the subtransient fault current that will flow if a 3 phase fault occurs at the high-voltage side of transformer 美。 AY G, ratings: sÓ MVA G2 ratings: 50 MVA T, ratings: 100 MVA 13.8/11 3AV X - 0.08 pu 13.8 AV 13.8 AV X"- 0.20 pu X"- 0.20 pu

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Two generators are connected in parallel to the low voltage side of a
transformer. Generators G1 and G 2 are each rated at 50 MVA, 13.8 kV,
with a subtransient resistance of 0.2 pu. Transformer T1 is rated at 100
MVA, 13.8/115 kV with a series reactance of 0.08 pu and negligible
resistance. Assume that initially the voltage on the high side of the
transformer is 120 kV, that the transformer is unloaded, and that there are
no circulating currents between the generators. Calculate the subtransient
fault current that will flow if a 3 phase fault occurs at the high-voltage
side of transformer
AY
Gz ratings:
50 MVA
G, ratings:
số MVA
13.8 KV
X" = 0.20 pu
T, ratings:
100 MVA
13.8/113 V
X - 0.08 pu
13.8 KV
X" - 0.20 pu
Choose the per-unit base values for this power system to be 100 MVA
and 13.8 kV
Transcribed Image Text:Two generators are connected in parallel to the low voltage side of a transformer. Generators G1 and G 2 are each rated at 50 MVA, 13.8 kV, with a subtransient resistance of 0.2 pu. Transformer T1 is rated at 100 MVA, 13.8/115 kV with a series reactance of 0.08 pu and negligible resistance. Assume that initially the voltage on the high side of the transformer is 120 kV, that the transformer is unloaded, and that there are no circulating currents between the generators. Calculate the subtransient fault current that will flow if a 3 phase fault occurs at the high-voltage side of transformer AY Gz ratings: 50 MVA G, ratings: số MVA 13.8 KV X" = 0.20 pu T, ratings: 100 MVA 13.8/113 V X - 0.08 pu 13.8 KV X" - 0.20 pu Choose the per-unit base values for this power system to be 100 MVA and 13.8 kV
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 2 images

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,