Three-phase, 50 Hz 34500/10500 delta-star connected transformer, single phase visible on high voltage (primary) windings side equivalent circuit parameters are given below. Each of the low voltage (secondary) windings of this transformer When a 7.5 ohm star connected resistive load is connected and the rated voltage is applied to the high voltage windings find transformer efficiency. Total iron losses of three phases will be taken as 85000 W. Primer sargı iç direnci (R1) Primer sargı kaçak reaktansı (X1) Sekonder sargı iç direnci (primere taşınmış) (R2') Sekonder sargı kaçak reaktansı (primere taşınmış) (X2') 1,25 2 1,85 2 1,25 2 1,82 2

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.16P: A single-phase, 50-kVA,2400/240-V,60-Hz distribution transformer has the following parameters:...
icon
Related questions
Question
Three-phase, 50 Hz 34500/10500 delta-star connected transformer, single phase visible on
high voltage (primary) windings side equivalent circuit parameters are given below.
Each of the low voltage (secondary) windings of this transformer
When a 7.5 ohm star connected resistive load is connected and the rated voltage is applied
to the high voltage windings find transformer efficiency.
Total iron losses of three phases will be taken as 8500o w.
Primer sargı kaçak
reaktansı (X1)
Sekonder sargı kaçak
reaktansı (primere
taşınmış) (X2')
1,25 2
Primer sargı iç direnci
(R1)
Sekonder sargı iç direnci
(primere taşınmış) (R2')
1,85 2
1,25 2
1,82 2
Transcribed Image Text:Three-phase, 50 Hz 34500/10500 delta-star connected transformer, single phase visible on high voltage (primary) windings side equivalent circuit parameters are given below. Each of the low voltage (secondary) windings of this transformer When a 7.5 ohm star connected resistive load is connected and the rated voltage is applied to the high voltage windings find transformer efficiency. Total iron losses of three phases will be taken as 8500o w. Primer sargı kaçak reaktansı (X1) Sekonder sargı kaçak reaktansı (primere taşınmış) (X2') 1,25 2 Primer sargı iç direnci (R1) Sekonder sargı iç direnci (primere taşınmış) (R2') 1,85 2 1,25 2 1,82 2
Expert Solution
steps

Step by step

Solved in 3 steps with 6 images

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning