Three identical steam-turbine generators G1, G2, and G3 are operating in parallel. Each generator is: 7.2 KV, 20 MVA, 50 Hz, 0.85 PF lagging, 4-poles, Y-connected, with a synchronous reactance of 2 Q and an armature resistance of 0.05 Q. Each of generators G, and G2 has a characteristic power-frequency slope of 4.7 MW/Hz, while generator G3 has a slope of 5.0 MW/Hz. If all three generators are supplying a total load of 51.2 MW, and the no-load frequency of each generator is set to 52.4 Hz, what will the system frequency be? How much power is supplied by generator G3? Select one: O a. fsys = 48.84 Hz, PG3 = 17.8 MW O b. fsys = 49.05 Hz, PG3 = 16.75 MW O c. fsys = 48.95 Hz, Pg3 = 17.25 MW O d. None

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Three identical steam-turbine generators G1, G2, and G3 are operating in parallel.
Each generator is: 7.2 KV, 20 MVA, 50 Hz, 0.85 PF lagging, 4-poles, Y-connected, with a synchronous reactance of 2 Q and an armature
resistance of 0.05 N.
Each of generators G1 and G2 has a characteristic power-frequency slope of 4.7 MW/Hz, while generator G3 has a slope of 5.0 MW/Hz.
If all three generators are supplying a total load of 51.2 MW, and the no-load frequency of each generator is set to 52.4 Hz, what will the
system frequency be? How much power is supplied by generator G3?
Select one:
O a. fsys = 48.84 Hz, PG3 = 17.8 MW
O b. fsys = 49.05 Hz, PG3 = 16.75 MW
O c. fsys = 48.95 Hz, PG3 = 17.25 MW
O d. None
Transcribed Image Text:Three identical steam-turbine generators G1, G2, and G3 are operating in parallel. Each generator is: 7.2 KV, 20 MVA, 50 Hz, 0.85 PF lagging, 4-poles, Y-connected, with a synchronous reactance of 2 Q and an armature resistance of 0.05 N. Each of generators G1 and G2 has a characteristic power-frequency slope of 4.7 MW/Hz, while generator G3 has a slope of 5.0 MW/Hz. If all three generators are supplying a total load of 51.2 MW, and the no-load frequency of each generator is set to 52.4 Hz, what will the system frequency be? How much power is supplied by generator G3? Select one: O a. fsys = 48.84 Hz, PG3 = 17.8 MW O b. fsys = 49.05 Hz, PG3 = 16.75 MW O c. fsys = 48.95 Hz, PG3 = 17.25 MW O d. None
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Stability Analysis in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,