Three Identical steam-turbine generators G 1 ,G 2 , and G 3 are operating in parallel Each generator is 7.2 KV,25.4 MVA, 60 Hz, 0.77 PF lagging 4 poles, Y- connected with synchronous reactance of 2 Ω and an armature resistance of 0.05 Ω. Each of generators G 1 and G 2 has a characteristic power frequency slope of 5.8 MW/ Hz , and no - load frequency of 62.5 Hz. Generator G 3 has a characteristic power- frequency slope of 6.0 MW/ Hz Find the no-load frequency of generator G 3 for which all generators supply a load of 42.6 MW, at Fsys=60Hz.
Three Identical steam-turbine generators G 1 ,G 2 , and G 3 are operating in parallel Each generator is 7.2 KV,25.4 MVA, 60 Hz, 0.77 PF lagging 4 poles, Y- connected with synchronous reactance of 2 Ω and an armature resistance of 0.05 Ω. Each of generators G 1 and G 2 has a characteristic power frequency slope of 5.8 MW/ Hz , and no - load frequency of 62.5 Hz. Generator G 3 has a characteristic power- frequency slope of 6.0 MW/ Hz Find the no-load frequency of generator G 3 for which all generators supply a load of 42.6 MW, at Fsys=60Hz.
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.16P: A single-phase, 120V(rms),60Hz source supplies power to a series R-L circuit consisting of R=10 and...
Related questions
Concept explainers
Synchronous Generator
In comparison to an asynchronous generator, it is a machine where the rotor speed is equal to the rotating magnetic field produced by the stator, i.e., mechanical speed is equal to the electrical speed, thus called synchronous, and not asynchronous.
Salient Pole Rotor
Salient pole rotor includes a large number of exposed poles mounted on a magnetic wheel. The construction of a bright pole is as shown in the image on the left. The proposed poles are made of metal laminations. The rotor winding is provided on these poles and is supported by pole shoes.
Question
Three Identical steam-turbine generators G 1 ,G 2 , and G 3 are operating in parallel
Each generator is 7.2 KV,25.4 MVA, 60 Hz, 0.77 PF lagging 4 poles, Y- connected with synchronous reactance of 2 Ω and an armature resistance of 0.05 Ω.
Each of generators G 1 and G 2 has a characteristic power frequency slope of 5.8 MW/ Hz , and no - load frequency of 62.5 Hz. Generator G 3 has a characteristic power- frequency slope of 6.0 MW/ Hz
Find the no-load frequency of generator G 3 for which all generators supply a load of 42.6 MW, at Fsys=60Hz.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning