Three columns x four rows of group piles are installed into a uniform clay layer. Clayey soil: Isat = 21.0 kN/m3, c = 40 kPa, Nc=7.5, Q=0.74 %D %3D Piles: Diameter d=0.3m, L=50m, pile spacing = 0.75m, pile edge distance=D0.45m (not shown in figure); f'c=35 MPa, db=20mm; fy=275 MPa %3D Pilecap : Effective Depth=550mm; f'c=30 MPa; db=28mm; fy=420 MPa Column : 500x500; f'c=28 MPa; db=32mm; fy=420 MPa Use a Factor of Safety of 4 Assuming the column and the pile cap has the same location of COG, and that the factored load acting on the column is 8580 kN, calculate the following: Applied Load, Q Pile Сap Side Friction A (B) Plan View Tip Bearing A

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
100%

1. Ultimate Capacity of the pile group considering single pile analysis, kN 

2. Allowable Capacity of the pile group considering block action analysis, kN

Three columns x four rows of group piles are
installed into a uniform clay layer.
Clayey soil: 7sat = 21.0 kN/m3 , c = 40 kPa, Nc=7.5,
a=0.74
Piles: Diameter d=0.3m, L=50m, pile spacing =
0.75m, pile edge distance=0.45m (not shown in
figure); f'c=35 MPa, db=20mm; fy=275 MPa
Pilecap : Effective Depth=550mm; f'c=30 MPa;
db=28mm; fy=420 MPa
Column : 500x500; f'c=28 MPa; db=32mm; fy=420
МPа
Use a Factor of Safety of 4
Assuming the column and the pile cap has the same
location of COG, and that the factored load acting on
the column is 8580 kN, calculate the following:
Applied Load, Q
Pile
Саp
В
Side
Friction
A
(B) Plan View
Tip
Bearing
(a) Side View
Transcribed Image Text:Three columns x four rows of group piles are installed into a uniform clay layer. Clayey soil: 7sat = 21.0 kN/m3 , c = 40 kPa, Nc=7.5, a=0.74 Piles: Diameter d=0.3m, L=50m, pile spacing = 0.75m, pile edge distance=0.45m (not shown in figure); f'c=35 MPa, db=20mm; fy=275 MPa Pilecap : Effective Depth=550mm; f'c=30 MPa; db=28mm; fy=420 MPa Column : 500x500; f'c=28 MPa; db=32mm; fy=420 МPа Use a Factor of Safety of 4 Assuming the column and the pile cap has the same location of COG, and that the factored load acting on the column is 8580 kN, calculate the following: Applied Load, Q Pile Саp В Side Friction A (B) Plan View Tip Bearing (a) Side View
Expert Solution
steps

Step by step

Solved in 3 steps with 1 images

Blurred answer
Knowledge Booster
Pricing excavation and backfill
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning