The Y-Y system of Fig below has a balanced load and a line impedance Z - at the generator is 16,000 V and the total power delivered to the load is 1200 kW at 80 A, determine each of the fol- lowing a. The magnitude of each phase voltage of the generator. b. The magniftude of the line cUrrents. c. The total power delivered by the source 40 +j 20 . If the line voltage

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
The Y-Y system of Fig below has a balanced load and a
line impedance Z - 40+j 200 If the line voltage
at the generator is 16,000 V and the total power delivered
to the load is 1200 kW at 80 A, determine each of the fol-
lowing
a. The magnitude of each phase voltage of the generator.
b. The magnitude of the line currents.
c. The total power delivered by the source
d. The power factor angle of the entire load "seen by
the source
e. The magnitude and angle of the current L, if E,N
EN /0
L The magnitude and angle of the phase voltage V-
g. The mpedance of the load of each phase in rectangu-
lar coordinates
h. The difference behween the power factor of the load
and the power factor of the entire system (including
i The efficiency of the system
000
20 12
42
2,-Z-Z
料
E-16 kV
2012
000
20 42
Transcribed Image Text:The Y-Y system of Fig below has a balanced load and a line impedance Z - 40+j 200 If the line voltage at the generator is 16,000 V and the total power delivered to the load is 1200 kW at 80 A, determine each of the fol- lowing a. The magnitude of each phase voltage of the generator. b. The magnitude of the line currents. c. The total power delivered by the source d. The power factor angle of the entire load "seen by the source e. The magnitude and angle of the current L, if E,N EN /0 L The magnitude and angle of the phase voltage V- g. The mpedance of the load of each phase in rectangu- lar coordinates h. The difference behween the power factor of the load and the power factor of the entire system (including i The efficiency of the system 000 20 12 42 2,-Z-Z 料 E-16 kV 2012 000 20 42
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Synchronous Generator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,