The three-plate moment connection shown below are all shop-welded to the column and then field bolted to the girder. The beam is a W18 55 that has a factored moment of Mu = 382 kip ft and a factored shear of Vu = 65 kip. All plates are A36 steel (Fy = 36 ksi, Fu = 58 ksi). Plate 2 is connected to the girder using four bolts as shown. All bolts for the connection are 7/8" diameter A325-X. • Design Plate 1, including the required number of bolts and dimensions of the plate. Assume an E70XX weld to the

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
The three-plate moment connection shown below are all
shop-welded to the column and then field bolted to the
girder. The beam is a W18 55 that has a factored moment of Mu
= 382 kip ft and a factored shear of Vu = 65 kip. All plates are
A36 steel (Fy = 36 ksi, Fu = 58 ksi). Plate 2 is connected to the
girder using four bolts as shown. All bolts for the connection
are 7/8" diameter A325-X.
• Design Plate 1, including the required number of bolts and
dimensions of the plate. Assume an E70XX weld to the
column. Consider limit states only for the plate itself. That
is, you do not need to consider limit states for the beam or
column.
• For which plate(s) will you need to check the buckling
capacity, Plate 1, 2, and/or 3? Explain.
Plate2
Plate 1
3.00" 2.50"
2.00"
2.75"
2.75"
2.75"
2.00"
Plate3
W18 55
Transcribed Image Text:The three-plate moment connection shown below are all shop-welded to the column and then field bolted to the girder. The beam is a W18 55 that has a factored moment of Mu = 382 kip ft and a factored shear of Vu = 65 kip. All plates are A36 steel (Fy = 36 ksi, Fu = 58 ksi). Plate 2 is connected to the girder using four bolts as shown. All bolts for the connection are 7/8" diameter A325-X. • Design Plate 1, including the required number of bolts and dimensions of the plate. Assume an E70XX weld to the column. Consider limit states only for the plate itself. That is, you do not need to consider limit states for the beam or column. • For which plate(s) will you need to check the buckling capacity, Plate 1, 2, and/or 3? Explain. Plate2 Plate 1 3.00" 2.50" 2.00" 2.75" 2.75" 2.75" 2.00" Plate3 W18 55
Expert Solution
steps

Step by step

Solved in 4 steps with 7 images

Blurred answer
Knowledge Booster
Cables
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning