The following Table gives the parameters for a transmission-distribution system. , This for the system .a) Draw the frequency domain equivalent circuit .b) Find the voltage across the load impedance as the phasor expression .c) Find the average, reactive and complex power transferred to the load .d) Calculate the power factor of the source .e) Find what percent of the average power is transferred to the load f) In order to make the power factor 1, the value of the circuit element to be connected parallel to the load find it Parameter Source (rms) Frequency Source Phase Angle source internal impedance Line Impedance Line Length Load Impedance Value 15kV 50hz 0 0,5+ j0.5 Q 0,02+j0,03 02/km 150km 26,5+j34,5 Ω

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
The following Table gives the parameters for a transmission-distribution system.
, This for the system
.a) Draw the frequency domain equivalent circuit
.b) Find the voltage across the load impedance as the phasor expression
.c) Find the average, reactive and complex power transferred to the load
.d) Calculate the power factor of the source
.e) Find what percent of the average power is transferred to the load
f) In order to make the power factor 1, the value of the circuit element to be connected
parallel to the load find it
Parameter
Source (rms)
Frequency
Source Phase Angle
source internal impedance
Line Impedance
Line Length
Load Impedance
Value
15kV
50hz
0
0,5+ j0.5 Q
0,02+j0,03 02/km
150km
26,5+j34,5 Ω
Transcribed Image Text:The following Table gives the parameters for a transmission-distribution system. , This for the system .a) Draw the frequency domain equivalent circuit .b) Find the voltage across the load impedance as the phasor expression .c) Find the average, reactive and complex power transferred to the load .d) Calculate the power factor of the source .e) Find what percent of the average power is transferred to the load f) In order to make the power factor 1, the value of the circuit element to be connected parallel to the load find it Parameter Source (rms) Frequency Source Phase Angle source internal impedance Line Impedance Line Length Load Impedance Value 15kV 50hz 0 0,5+ j0.5 Q 0,02+j0,03 02/km 150km 26,5+j34,5 Ω
Expert Solution
steps

Step by step

Solved in 5 steps with 4 images

Blurred answer
Knowledge Booster
Sinusoids and Phasors of Alternating Circuit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,