12:28 团 4G75% SimplePartDocument.pdf - Read-only لا کا This account does not allow editing on... DustGuard™ system spray nozzles, ⚫ Wash hose. Solution Flow Control The electric solution pump and main solution solenoid valve control the solution flow to the main scrub brushes. The main solution solenoid valve opens when the solution system switches on. A Pulsed Width Modulated (PWM) output from J3-2 on the Drive Box controls the speed of the solution pump to regulate solution flow to the brushes. Service Manual - SC8000 Solution System 164 Detergent System The AXP/EDS and EcoFlex detergent systems use dual diaphragm Detergent Pumps (M10 and M11) to pump detergent into the solution flow upstream of the Main Solution Solenoid Valve (110). Two Detergent Pumps are used to ensure adequate detergent supply at the higher detergent and solution flow rates. The Driver Box sends voltage to the Detergent Pumps that changes polarity and dwell time to regulate the detergent dispense rate according to the solution flow rate. The Detergent Supply Line from the Detergent Cartridge is split into two lines, one feeding each Detergent Pump. The two lines from the Detergent Pumps merge into one Detergent Supply Line, which is then connected to the Solution Hose upstream of the Main Solution Solenoid Valve. Main Solution Solenoid Valve Tee (1) Solution Hose Tee (2) Detergent Supply Line (to Pumps) Detergent Pumps Detergent Supply Detergent Cartridge (2) Line (to Solution Hose) The Tee (1) by the Main Solution Solenoid Valve provides solution to the right front scrub brush (if the machine is so equipped). The Tee (2) upstream of the Detergent Supply Line provides solution from the recovery tank for the extended scrub system (if the machine is so equipped). = III O Г STER 50

International Edition---engineering Mechanics: Statics, 4th Edition
4th Edition
ISBN:9781305501607
Author:Andrew Pytel And Jaan Kiusalaas
Publisher:Andrew Pytel And Jaan Kiusalaas
Chapter9: Moments And Products Of Inertia Of Areas
Section: Chapter Questions
Problem 9.46P
icon
Related questions
Question
What kind of detergent do you use with a sc8000 industrial automatic scrubber/sweeper?
12:28 团
4G75%
SimplePartDocument.pdf - Read-only
لا کا
This account does not allow editing on...
DustGuard™ system spray nozzles,
⚫ Wash hose.
Solution Flow Control
The electric solution pump and main solution solenoid valve control the solution flow to the main scrub
brushes. The main solution solenoid valve opens when the solution system switches on. A Pulsed Width
Modulated (PWM) output from J3-2 on the Drive Box controls the speed of the solution pump to regulate
solution flow to the brushes.
Service Manual - SC8000
Solution System 164
Detergent System
The AXP/EDS and
EcoFlex detergent
systems use dual
diaphragm Detergent
Pumps (M10 and M11) to
pump detergent into the
solution flow upstream of
the Main Solution Solenoid
Valve (110). Two Detergent
Pumps are used to ensure
adequate detergent supply
at the higher detergent
and solution flow rates.
The Driver Box sends
voltage to the Detergent
Pumps that changes
polarity and dwell time
to regulate the detergent
dispense rate according to
the solution flow rate.
The Detergent Supply
Line from the Detergent
Cartridge is split into two
lines, one feeding each
Detergent Pump. The two
lines from the Detergent
Pumps merge into one
Detergent Supply Line,
which is then connected to
the Solution Hose upstream
of the Main Solution
Solenoid Valve.
Main
Solution
Solenoid
Valve
Tee (1)
Solution
Hose
Tee (2)
Detergent
Supply
Line (to
Pumps)
Detergent
Pumps
Detergent
Supply
Detergent
Cartridge (2)
Line (to
Solution
Hose)
The Tee (1) by the Main Solution Solenoid Valve provides solution to the right front scrub brush (if the machine
is so equipped).
The Tee (2) upstream of the Detergent Supply Line provides solution from the recovery tank for the extended
scrub system (if the machine is so equipped).
=
III
O
Г
Transcribed Image Text:12:28 团 4G75% SimplePartDocument.pdf - Read-only لا کا This account does not allow editing on... DustGuard™ system spray nozzles, ⚫ Wash hose. Solution Flow Control The electric solution pump and main solution solenoid valve control the solution flow to the main scrub brushes. The main solution solenoid valve opens when the solution system switches on. A Pulsed Width Modulated (PWM) output from J3-2 on the Drive Box controls the speed of the solution pump to regulate solution flow to the brushes. Service Manual - SC8000 Solution System 164 Detergent System The AXP/EDS and EcoFlex detergent systems use dual diaphragm Detergent Pumps (M10 and M11) to pump detergent into the solution flow upstream of the Main Solution Solenoid Valve (110). Two Detergent Pumps are used to ensure adequate detergent supply at the higher detergent and solution flow rates. The Driver Box sends voltage to the Detergent Pumps that changes polarity and dwell time to regulate the detergent dispense rate according to the solution flow rate. The Detergent Supply Line from the Detergent Cartridge is split into two lines, one feeding each Detergent Pump. The two lines from the Detergent Pumps merge into one Detergent Supply Line, which is then connected to the Solution Hose upstream of the Main Solution Solenoid Valve. Main Solution Solenoid Valve Tee (1) Solution Hose Tee (2) Detergent Supply Line (to Pumps) Detergent Pumps Detergent Supply Detergent Cartridge (2) Line (to Solution Hose) The Tee (1) by the Main Solution Solenoid Valve provides solution to the right front scrub brush (if the machine is so equipped). The Tee (2) upstream of the Detergent Supply Line provides solution from the recovery tank for the extended scrub system (if the machine is so equipped). = III O Г
STER 50
Transcribed Image Text:STER 50
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
International Edition---engineering Mechanics: St…
International Edition---engineering Mechanics: St…
Mechanical Engineering
ISBN:
9781305501607
Author:
Andrew Pytel And Jaan Kiusalaas
Publisher:
CENGAGE L