QUESTION 5 (a) A PMMC instrument with a f.s.d of 10µA and Rm = 10002 to be employed as a voltmeter with range of 10V, 50V and 100V. Calculate the required values of multiplier resistors for the circuits of Figure 5(a)-i and Figure Q5(a.ii). Ry R1 R S0V 10v 10V 50V 100V 100V (i) (ii) Figure Q5(a) (b) Two voltmeter are used to measure the voltage across the 50k2 resistor in the circuit shown in Figure QS(b). Meter A has ac sensitivity of 10k2V, a guaranteed accuracy of 97% at full scale, and is set on its 200V range. Meter B has an ac sensitivity of 4k2V, a guaranteed accuracy of 98% at full scale and is set on its 100V range. Which meter will provide a more accurate result?

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
QUESTION 5
(a)
A PMMC instrument with a f.s.d of 10pA and Rm = 10002 to be employed as a
voltmeter with range of 10V, 50V and 100V. Calculate the required values of
multiplier resistors for the circuits of Figure 5(a)-i and Figure Q5(a.ii).
R3
R3
R1
R,
R R.
50V
10V
10V
50V
100V
100V
(i)
(ii)
Figure Q5(a)
(b)
Two voltmeter are used to measure the voltage across the 50kn resistor in the circuit
shown in Figure QS(b), Meter A has ac sensitivity of 10K2V, a guaranteed accuracy
of 97% at full scale, and is set on its 200V range. Meter B has an ac sensitivity of
4KNV, a guaranteed accuracy of 98% at full scale and is set on its 100V range. Which
meter will provide a more accurate result?
10k
R1
R 15k
V- 120Vrms
Ry 50k
Figure Q5(b)
Transcribed Image Text:QUESTION 5 (a) A PMMC instrument with a f.s.d of 10pA and Rm = 10002 to be employed as a voltmeter with range of 10V, 50V and 100V. Calculate the required values of multiplier resistors for the circuits of Figure 5(a)-i and Figure Q5(a.ii). R3 R3 R1 R, R R. 50V 10V 10V 50V 100V 100V (i) (ii) Figure Q5(a) (b) Two voltmeter are used to measure the voltage across the 50kn resistor in the circuit shown in Figure QS(b), Meter A has ac sensitivity of 10K2V, a guaranteed accuracy of 97% at full scale, and is set on its 200V range. Meter B has an ac sensitivity of 4KNV, a guaranteed accuracy of 98% at full scale and is set on its 100V range. Which meter will provide a more accurate result? 10k R1 R 15k V- 120Vrms Ry 50k Figure Q5(b)
Expert Solution
steps

Step by step

Solved in 5 steps with 4 images

Blurred answer
Knowledge Booster
Inductor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,