Question 5 (20 marks) For the circuit in figure 5, complete the following: Calculate complex power for total load. Total load is combination of two parallel loads. i. ii. Calculate average power for total load. iii. Calculate reactive power for total load. iv. Calculate apparent power for total load. V. Calculate power factor for total load. [9 marks] [1 mark] [1 mark] [1 mark] [2 marks] [3 marks] [2 marks] [1 mark] vi. vii. viii. RMS value for the current I shown in figure 5. Determine average power absorbed by the 40 resistor. Determine average power absorbed by the -j100 capacitor. 4 Ohms + Vs ww+> / -j10 Ohms + 240/0 RMS 0.8 Lagging 86 KVA 36 KWatts 54 KVAR Fig.5: Circuit for Q5

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter5: Transmission Lines: Steady-state Operation
Section: Chapter Questions
Problem 5.25MCQ
icon
Related questions
Question
Don't use ai to answer I will report you answer
Question 5 (20 marks)
For the circuit in figure 5, complete the following:
Calculate complex power for total load. Total load is combination of two
parallel loads.
i.
ii.
Calculate average power for total load.
iii.
Calculate reactive power for total load.
iv.
Calculate apparent power for total load.
V.
Calculate power factor for total load.
[9 marks]
[1 mark]
[1 mark]
[1 mark]
[2 marks]
[3 marks]
[2 marks]
[1 mark]
vi.
vii.
viii.
RMS value for the current I shown in figure 5.
Determine average power absorbed by the 40 resistor.
Determine average power absorbed by the -j100 capacitor.
4 Ohms
+ Vs
ww+>
/
-j10 Ohms
+
240/0
RMS
0.8 Lagging
86 KVA
36 KWatts
54 KVAR
Fig.5: Circuit for Q5
Transcribed Image Text:Question 5 (20 marks) For the circuit in figure 5, complete the following: Calculate complex power for total load. Total load is combination of two parallel loads. i. ii. Calculate average power for total load. iii. Calculate reactive power for total load. iv. Calculate apparent power for total load. V. Calculate power factor for total load. [9 marks] [1 mark] [1 mark] [1 mark] [2 marks] [3 marks] [2 marks] [1 mark] vi. vii. viii. RMS value for the current I shown in figure 5. Determine average power absorbed by the 40 resistor. Determine average power absorbed by the -j100 capacitor. 4 Ohms + Vs ww+> / -j10 Ohms + 240/0 RMS 0.8 Lagging 86 KVA 36 KWatts 54 KVAR Fig.5: Circuit for Q5
Expert Solution
steps

Step by step

Solved in 2 steps with 5 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning