QUESTION 21 Can the MRecovery of a sample come larger than 100, if the analysis is carried under the internasi standard formalism? (mutiple answers) yes, if there were air bubbles in the volumetric pipette(s) when the standard stock solutions were transferred to the common volumetric flask, for the preparation of the combined standard for injection. yes, if the injector of the HPLC system was unreliable and it injected irreproducible volumes of standard and sample yes, if the HPLC vials were kept un-capped, so that their content evaporated at different rates between the time they were placed in the tray of the HPLC system and the time of the injections. yes, if the final volume of sample or of combined standard for injection was inaccurately brought to the mark of the volumetric flask yes, if the standard preparation was less concentrated than required by the protocol, due to errors in weighing the standard materials a weaker sta make all samples quantitated against if look stronger. standard would yes, if there was incomplete dissolution of the solid sample in the preparation of the sample stock solution yes, if we blame errors that ocurred before the internal standard substance arrived in any of the preparations yes, if the stock sample solution was kept uncovered and the solvent evaporated, thus concentrating the stock sample solution

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question
QUESTION 21
Can the %Recovery of a sample come larger than 100%, if the analysis is carried under the intermasi stardard formalism? (multiple answers)
yes, if there were air bubbles in the volumetric pipette(s) when the standard stock solutions were transferred to thye common volumetric flask, for the
preparation of the combined standard for injection.
yes, if the injector of the HPLC system was unreliable and it injected irreproducible volumes of standard and sample
yes, if the HPLC vials were kept un-capped, so that their content evaporated at different rates between the time they were placed in the tray of the HPLC system
and the time of the injections.
yes, if the final volume of sample or of combined standard for injection was inaccurately brought to the mark of the volumetric flask.
yes, if the standard preparation was less concentrated than required by the protocol, due to errors in weighing the standard materials, a weaker standard would
make all samples quantitated against if look stronger.
yes, if there was incomplete dissolution of the solid sample in the preparation of the sample stock solution
yes, if we blame errors that ocurred before the internal standard substance arrived in any of the preparations
yes, if the stock sample solution was kept uncovered and the solvent evaporated, thus concentrating the stock sample solution
Transcribed Image Text:QUESTION 21 Can the %Recovery of a sample come larger than 100%, if the analysis is carried under the intermasi stardard formalism? (multiple answers) yes, if there were air bubbles in the volumetric pipette(s) when the standard stock solutions were transferred to thye common volumetric flask, for the preparation of the combined standard for injection. yes, if the injector of the HPLC system was unreliable and it injected irreproducible volumes of standard and sample yes, if the HPLC vials were kept un-capped, so that their content evaporated at different rates between the time they were placed in the tray of the HPLC system and the time of the injections. yes, if the final volume of sample or of combined standard for injection was inaccurately brought to the mark of the volumetric flask. yes, if the standard preparation was less concentrated than required by the protocol, due to errors in weighing the standard materials, a weaker standard would make all samples quantitated against if look stronger. yes, if there was incomplete dissolution of the solid sample in the preparation of the sample stock solution yes, if we blame errors that ocurred before the internal standard substance arrived in any of the preparations yes, if the stock sample solution was kept uncovered and the solvent evaporated, thus concentrating the stock sample solution
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Quality Assurance and Calibration Methods
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY