The copper in a contaminated water sample was determined by atomic absorption flame spectroscopy. First 10.0 mL of the unknown was pipetted into each of five 50.0 mL volumetric flasks. Various volumes of a standard stock solution containing 12.2 ppm Cu were added to the flasks, and the solutions were then diluted to volume. Volume of Unknown/ mL Volume of Standard/mL [Cu ]/ppm Absorbance 10 0 0.201 10 10 0.292 10 20 0.378 10 30 0.467 10 40 0.554 a) Determine the Cu concentration in each solution from the standard in ppm. b) Plot absorbance as a function of the Cu concentration on a plot (which is included) using spreadsheet software and include appropriate axis labels. c) Determine values for the slope and intercept from the line of best fit to the data. d) Determine the concentration of Cu in the original water sample. hi

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question
None
The copper in a contaminated water sample was
determined by atomic absorption flame spectroscopy.
First 10.0 mL of the unknown was pipetted into each of
five 50.0 mL volumetric flasks. Various volumes of a
standard stock solution containing 12.2 ppm Cu were
added to the flasks, and the solutions were then diluted
to volume.
Volume of Unknown/ mL Volume of Standard/mL [Cu
]/ppm Absorbance
10 0
0.201
10 10
0.292
10 20 0.378
10 30
0.467
10 40
0.554
a) Determine the Cu concentration in each solution
from the standard in ppm.
b) Plot absorbance as a function of the Cu
concentration on a plot (which is included) using
spreadsheet software and include appropriate axis
labels.
c) Determine values for the slope and intercept from the
line of best fit to the data.
d) Determine the concentration of Cu in the original
water sample.
hi
Transcribed Image Text:The copper in a contaminated water sample was determined by atomic absorption flame spectroscopy. First 10.0 mL of the unknown was pipetted into each of five 50.0 mL volumetric flasks. Various volumes of a standard stock solution containing 12.2 ppm Cu were added to the flasks, and the solutions were then diluted to volume. Volume of Unknown/ mL Volume of Standard/mL [Cu ]/ppm Absorbance 10 0 0.201 10 10 0.292 10 20 0.378 10 30 0.467 10 40 0.554 a) Determine the Cu concentration in each solution from the standard in ppm. b) Plot absorbance as a function of the Cu concentration on a plot (which is included) using spreadsheet software and include appropriate axis labels. c) Determine values for the slope and intercept from the line of best fit to the data. d) Determine the concentration of Cu in the original water sample. hi
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY