Q4. Figure Q4. shows a power system with one generator, two transformers, a line and a load. G Vgen-415/0°V от R = 0.02 600 kVA 0.415/11 kV Y-Y XT1=6% ZLine=1+j0.1 tot Zload=0.3+j0.102 500 kVA 11/0.415 kV Y-Y XT2=5% Figure Q4. A Simple Power System a) i. ii. The one-line diagram shown in Figure Q4. is a proposal for a new power system. Assuming a base apparent power of 600 kVA and a base voltage of 11 kV in the line section: Calculate the Current magnitudes in the generator, line and load sections Calculate the overall system power factor iii. Obtain the system losses at rated operating conditions, and the potential for series power factor correction, stating the value of the capacitor necessary to bring the system power factor to unity.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter4: Transmission Line Parameters
Section: Chapter Questions
Problem 4.8MCQ: An ac resistance is higher than a dc resistance. True False
icon
Related questions
Question
Q4. Figure Q4. shows a power system with one generator, two transformers, a line
and a load.
G
Vgen-415/0°V
от
R = 0.02
600 kVA
0.415/11 kV Y-Y
XT1=6%
ZLine=1+j0.1
tot
Zload=0.3+j0.102
500 kVA
11/0.415 kV Y-Y
XT2=5%
Figure Q4. A Simple Power System
a)
i.
ii.
The one-line diagram shown in Figure Q4. is a proposal for a new power
system. Assuming a base apparent power of 600 kVA and a base voltage
of 11 kV in the line section:
Calculate the Current magnitudes in the generator, line and load
sections
Calculate the overall system power factor
iii.
Obtain the system losses at rated operating conditions, and the potential
for series power factor correction, stating the value of the capacitor
necessary to bring the system power factor to unity.
Transcribed Image Text:Q4. Figure Q4. shows a power system with one generator, two transformers, a line and a load. G Vgen-415/0°V от R = 0.02 600 kVA 0.415/11 kV Y-Y XT1=6% ZLine=1+j0.1 tot Zload=0.3+j0.102 500 kVA 11/0.415 kV Y-Y XT2=5% Figure Q4. A Simple Power System a) i. ii. The one-line diagram shown in Figure Q4. is a proposal for a new power system. Assuming a base apparent power of 600 kVA and a base voltage of 11 kV in the line section: Calculate the Current magnitudes in the generator, line and load sections Calculate the overall system power factor iii. Obtain the system losses at rated operating conditions, and the potential for series power factor correction, stating the value of the capacitor necessary to bring the system power factor to unity.
Expert Solution
steps

Step by step

Solved in 2 steps with 4 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning