Problem 3 Consider the following system. TO T. j0.05 fmy(G j0.05 M) Δ YA The generator and motor are both rated 600 V, 1.2MVA with per-unit impedances X;=X;=X =0.1 and X=0.05. The transformers are rated 600 V(A)-3.3kv(Y), 1.2 MVA with X=0.05 pu . The transmission line has per-unit impedances X;=X,=0.2 and X,=0.4 on a base of 1.2MVA , 3.3kV. Draw the positive-, negative-, and zero-sequence equivalent circuits.
Problem 3 Consider the following system. TO T. j0.05 fmy(G j0.05 M) Δ YA The generator and motor are both rated 600 V, 1.2MVA with per-unit impedances X;=X;=X =0.1 and X=0.05. The transformers are rated 600 V(A)-3.3kv(Y), 1.2 MVA with X=0.05 pu . The transmission line has per-unit impedances X;=X,=0.2 and X,=0.4 on a base of 1.2MVA , 3.3kV. Draw the positive-, negative-, and zero-sequence equivalent circuits.
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter7: Symmetrical Faults
Section: Chapter Questions
Problem 7.3MCQ: The amplitude of the sinusoidal symmetrical ac component of the three-phase short-circuit current of...
Related questions
Question
![Problem 3
Consider the following system.
TO
T,
j0.05
fmy(G
j0.05
YA
The generator and motor are both rated 600 V, 1.2MVA with per-unit impedances
X;=X;=x=0.1 and X=0.05. The transformers are rated 600 V (A)-3.3kv(Y),
1.2 MVA with X=0.05 pu . The transmission line has per-unit impedances X;=X,=0.2 and
X,=0.4 on a base of 1.2MVA , 3.3kV .
Draw the positive-, negative-, and zero-sequence equivalent circuits.](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2Fb5312a15-860e-407c-ae9e-8729c86c8316%2F46efdf43-e4a1-4e80-bc3a-ee9b61cb6ed9%2F64wl49ln_processed.png&w=3840&q=75)
Transcribed Image Text:Problem 3
Consider the following system.
TO
T,
j0.05
fmy(G
j0.05
YA
The generator and motor are both rated 600 V, 1.2MVA with per-unit impedances
X;=X;=x=0.1 and X=0.05. The transformers are rated 600 V (A)-3.3kv(Y),
1.2 MVA with X=0.05 pu . The transmission line has per-unit impedances X;=X,=0.2 and
X,=0.4 on a base of 1.2MVA , 3.3kV .
Draw the positive-, negative-, and zero-sequence equivalent circuits.
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 3 steps with 2 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning