Please answer all 5 questions (it could be short answers). 5-1. What is the main barrier to separating liquid mixtures of less than 500 mL by distillation? 5-2. A sample mixture of ethyl benzoate (bp 212 Celsius) and dodecane (bp 216.2 Celsius) is injected on two GC columns. Column A has DC710 silicone oil as the stationary phase, and column B uses polyethylene glycol as the stationary phase. Which substance would be certain to elute first from column A and would the same material be expected to elute first from column B? Which column, A or B, would be expected to give the better separation of these two substances?

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question
100%

Please answer all 5 questions (it could be short answers).

5-1. What is the main barrier to separating liquid mixtures of less than 500 mL by distillation?

5-2. A sample mixture of ethyl benzoate (bp 212 Celsius) and dodecane (bp 216.2 Celsius) is injected on two GC columns. Column A has DC710 silicone oil as the stationary phase, and column B uses polyethylene glycol as the stationary phase. Which substance would be certain to elute first from column A and would the same material be expected to elute first from column B? Which column, A or B, would be expected to give the better separation of these two substances?

5-3. Question 5-2 refers to separating a mixture of two high boiling liquids by gas chromatography. These materials have similar boiling points. List several GC variables and conditions that would make it easier to separate these
substances by gas chromatography

5-4. Capillary GC columns have better resolution than packed columns even though the enormous surface area provided by the packing material is absent in capillary columns. Why?

5-5. Preparative GC requires packed columns. Why is this technique limited to these lower resolution columns?

Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Sample Preparation in Analytical Chemistry
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY