On a base of 25 MVA , 11 kV the generator has reactances X,=X;=X;=0.2 pu and X = 0.06 pu . It is Y configured and the neutral is grounded through an impedance j 2.52. On a base of 15MVA, 11KV motor M; has reactances X;=X;=X=0.25 pu and X g=0.06 pu . It is Y configured and the neutral is isolated. On a base of 7.5 MVA , 11 kV motor M, has reactances X;=X;=X;=0.25 pu and X =0.06 pu . It is Y configured and the neutral is grounded through an impedance j 2.52. Both transformers are rated 30 MVA, 11kV(A)-120kV(Y) with reactance X=0.1pu . The neutral of the Y is solidly grounded. The transmission line reactances are labeled. Draw the positive-, negative-, and zero-sequence equivalent circuits.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
M)Y
j 2.50
my(G
X,=X,=100N
X,=3002
j 2.52
AY
Δ
On a base of 25 MVA , 11 kV the generator has reactances X,=X,=X;=0.2 pu and
X= 0.06 pu . It is Y configured and the neutral is grounded through an impedance j 2.50.
On a base of 15MVA, 11kV motor M, has reactances X;=X;=X=0.25 pu and
X =0.06 pu . It is Y configured and the neutral is isolated.
On a base of 7.5 MVA , 11kV motor M, has reactances X;=X,=X=0.25 pu and
X =0.06 pu . It is Y configured and the neutral is grounded through an impedance j2.52.
Both transformers are rated 30 MVA, 11kV(A)-120kV(Y) with reactance X=0.1 pu . The
neutral of the Y is solidly grounded. The transmission line reactances are labeled.
Draw the positive-, negative-, and zero-sequence equivalent circuits.
Transcribed Image Text:M)Y j 2.50 my(G X,=X,=100N X,=3002 j 2.52 AY Δ On a base of 25 MVA , 11 kV the generator has reactances X,=X,=X;=0.2 pu and X= 0.06 pu . It is Y configured and the neutral is grounded through an impedance j 2.50. On a base of 15MVA, 11kV motor M, has reactances X;=X;=X=0.25 pu and X =0.06 pu . It is Y configured and the neutral is isolated. On a base of 7.5 MVA , 11kV motor M, has reactances X;=X,=X=0.25 pu and X =0.06 pu . It is Y configured and the neutral is grounded through an impedance j2.52. Both transformers are rated 30 MVA, 11kV(A)-120kV(Y) with reactance X=0.1 pu . The neutral of the Y is solidly grounded. The transmission line reactances are labeled. Draw the positive-, negative-, and zero-sequence equivalent circuits.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
DC Generator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,