Given three single phase step down distribution transformers with rated capacity each TR=100KVA and input - output voltages 20KV - 110V X 220V. Use this transformer to build the following three phases transformers connection (complete the connection). 1) Star- Star 300KVA step down three phases transformer bank 20KV - 220V with 0° angular displacement Three Phases - Three wires Star Primary A V=20KV V=20KV C A C H1 H2 H1 H2 H1 H2 X4 X3x2 X10 X4 X3x2 X10 X4 X3x2 X10 a V=220V b V-220V Three Phases - Three wires Star Secondary 2) Calculate the line current Ia, Ib and le (at the secondary) in case a balanced star load 180KVA with lagging power factor PF=0.8 is connected to the outputs of the STAR-STAR transformer in part a.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Given three single phase step down distribution transformers with rated capacity each TR=100KVA
and input - output voltages 20KV - 110V X 220V. Use this transformer to build the following three
phases transformers connection (complete the connection).
1) Star- Star 300KVA step down three phases transformer bank 20KV - 220V with 0° angular
displacement
Three Phases - Three wires Star Primary
A
V=20KV
V=20KV
A
H1
H2
H1
H2
H1
H2
00000n 00,
00000n 00,
00000n 000-
X4
X30x2
X10
OX4
X30x2
X1
X4
X3 x2
X10
b
a
V=220V
b
V=220V
a
Three Phases - Three wires Star Secondary
2) Calculate the line current Ia, Ib and Ic (at the secondary) in case a balanced star load 180KVA with
lagging power factor PF=0.8 is connected to the outputs of the STAR-STAR transformer in part a.
Transcribed Image Text:Given three single phase step down distribution transformers with rated capacity each TR=100KVA and input - output voltages 20KV - 110V X 220V. Use this transformer to build the following three phases transformers connection (complete the connection). 1) Star- Star 300KVA step down three phases transformer bank 20KV - 220V with 0° angular displacement Three Phases - Three wires Star Primary A V=20KV V=20KV A H1 H2 H1 H2 H1 H2 00000n 00, 00000n 00, 00000n 000- X4 X30x2 X10 OX4 X30x2 X1 X4 X3 x2 X10 b a V=220V b V=220V a Three Phases - Three wires Star Secondary 2) Calculate the line current Ia, Ib and Ic (at the secondary) in case a balanced star load 180KVA with lagging power factor PF=0.8 is connected to the outputs of the STAR-STAR transformer in part a.
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,