A 3-phase transformer is assembled by connecting three 720 -VA, 360/120 V single phase transformers in Y-delta connection. The constants for each transformer are. On HV side R₁=18.9 ohm X₁= 21.6 ohm On low voltage side R₂= 2.1 ohm X₂ = 2.4 ohm Obtain per phase equivalent circuit of this 3-phase transformer. What is the line-voltage rating and VA rating of the 3-phase transformer? HINT: convert to Y first If the secondary side is connected to a load which draws half of rated current at 0.5 power factor at rated voltage, what is the line voltage applied to the 3-phase transformer?

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

Please answer all subpart either dislike is ready

Please ASAP for like please 

A 3-phase transformer is assembled by connecting three 720 -VA, 360/120 V single phase
transformers in Y-delta connection. The constants for each transformer are.
On HV side R₁-18.9 ohm X₁= 21.6 ohm On low voltage side R₂= 2.1 ohm X₂ = 2.4 ohm
Obtain per phase equivalent circuit of this 3-phase transformer.
What is the line-voltage rating and VA rating of the 3-phase transformer?
HINT: convert to Y first
If the secondary side is connected to a load which draws half of rated current at 0.5 power
factor at rated voltage, what is the line voltage applied to the 3-phase transformer?
Transcribed Image Text:A 3-phase transformer is assembled by connecting three 720 -VA, 360/120 V single phase transformers in Y-delta connection. The constants for each transformer are. On HV side R₁-18.9 ohm X₁= 21.6 ohm On low voltage side R₂= 2.1 ohm X₂ = 2.4 ohm Obtain per phase equivalent circuit of this 3-phase transformer. What is the line-voltage rating and VA rating of the 3-phase transformer? HINT: convert to Y first If the secondary side is connected to a load which draws half of rated current at 0.5 power factor at rated voltage, what is the line voltage applied to the 3-phase transformer?
Expert Solution
steps

Step by step

Solved in 6 steps with 9 images

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,