Find the loss in total pressure for each run in the simple duct system of Fig. 1, using the equal-friction method and in English unit. The total pressure available for the duct system is 0.12 in. wg (30 Pa), and the loss in total pressure for each diffuser at the specified flow rate is 0.02 in. wg (5 Pa). Duct fittings are listed in Table 1. Assume the duct dimeter in run 1 is 10 in. and the rest are 8 in. Does the duct system require any adjustment? 150 cfm a 15 ft Plenum e 15 ft 5 ft a d. 5 ft 20 ft 10 ft 200 cfm e 10 ft 150 cfm b Duct Fittings for Figure 1 Fittings Type Abrupt Entrance 90 deg Elbow, Pleated Round to Rectangular boot, Straight 45 deg. Converging Wye 45 deg Elbow, Pleated a C d. e

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
Find the loss in total pressure for each run in the simple duct system of Fig. 1, using the
equal-friction method and in English unit. The total pressure available for the duct system
is 0.12 in. wg (30 Pa), and the loss in total pressure for each diffuser at the specified flow
rate is 0.02 in. wg (5 Pa). Duct fittings are listed in Table 1. Assume the duct dimeter in
run 1 is 10 in. and the rest are 8 in. Does the duct system require any adjustment?
150 cfm
e.
a
15 ft
Plenum
е
15 ft
5 ft
5 ft
a
3.
20 ft
4
10 ft
200 cfm
e
10 ft
150 cfm
b
Duct Fittings for Figure 1
Fittings Type
Abrupt Entrance
90 deg Elbow, Pleated
Round to Rectangular boot, Straight
45 deg. Converging Wye
45 deg Elbow, Pleated
a
d
e
Transcribed Image Text:Find the loss in total pressure for each run in the simple duct system of Fig. 1, using the equal-friction method and in English unit. The total pressure available for the duct system is 0.12 in. wg (30 Pa), and the loss in total pressure for each diffuser at the specified flow rate is 0.02 in. wg (5 Pa). Duct fittings are listed in Table 1. Assume the duct dimeter in run 1 is 10 in. and the rest are 8 in. Does the duct system require any adjustment? 150 cfm e. a 15 ft Plenum е 15 ft 5 ft 5 ft a 3. 20 ft 4 10 ft 200 cfm e 10 ft 150 cfm b Duct Fittings for Figure 1 Fittings Type Abrupt Entrance 90 deg Elbow, Pleated Round to Rectangular boot, Straight 45 deg. Converging Wye 45 deg Elbow, Pleated a d e
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Applied Fluid Mechanics
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY