D&D Inc operations area personnel are experiencing problems with a particular feedback control loop on an interstage cooler. Your supervisor has asked you to assess the situation and report back solutions if any are available. The control loop is exhibiting an undesirable sustained oscillation that the operations group are sure is caused by the feedback loop itself (poor controller tuning). They want assistance in retuning the controller. Your supervisor thinks that the oscillations are caused by external disturbances and wants the operations group personnel to deal with the problem themselves. Suggest a simple procedure that will allow you to determine quickly the cause of the oscillations. How will you explain your logic to your supervisor?

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
D&D Inc operations area personnel are experiencing problems with a particular feedback control loop on
an interstage cooler. Your supervisor has asked you to assess the situation and report back solutions if any
are available. The control loop is exhibiting an undesirable sustained oscillation that the operations group
are sure is caused by the feedback loop itself (poor controller tuning). They want assistance in retuning the
controller. Your supervisor thinks that the oscillations are caused by external disturbances and wants the
operations group personnel to deal with the problem themselves. Suggest a simple procedure that will
allow you to determine quickly the cause of the oscillations. How will you explain your logic to your
supervisor?
Transcribed Image Text:D&D Inc operations area personnel are experiencing problems with a particular feedback control loop on an interstage cooler. Your supervisor has asked you to assess the situation and report back solutions if any are available. The control loop is exhibiting an undesirable sustained oscillation that the operations group are sure is caused by the feedback loop itself (poor controller tuning). They want assistance in retuning the controller. Your supervisor thinks that the oscillations are caused by external disturbances and wants the operations group personnel to deal with the problem themselves. Suggest a simple procedure that will allow you to determine quickly the cause of the oscillations. How will you explain your logic to your supervisor?
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The