HIGHAI leedback control. The set point on the P-controller (PC) is 20 psig, and at stendy-state the controller output signal is 12 mA. The controller output signal is sent to a current-to-pressure transducer (KIP) in order to adjust the air-operated control valve on the exit line. The transmitter (PT) has a calibrated input range of 0-50 psig, a 4-20 mA output range and negligible time pressure constant. (a) What is your recommendation for the control valve? Fail-open or fail-close? Air-to-open or air-to- closc? Explain the reasons for your choice. (b) Should the proportional controller be direct-acting or reverse-acting for safe operation of the process? Explain your reasons for your selection. (c) The controller gain setting is Ke =2.0 If the gas surge tank pressure suddenly increases to 25 psig, calculate the controller output signal in units of mA immediately after the pressure increase.
HIGHAI leedback control. The set point on the P-controller (PC) is 20 psig, and at stendy-state the controller output signal is 12 mA. The controller output signal is sent to a current-to-pressure transducer (KIP) in order to adjust the air-operated control valve on the exit line. The transmitter (PT) has a calibrated input range of 0-50 psig, a 4-20 mA output range and negligible time pressure constant. (a) What is your recommendation for the control valve? Fail-open or fail-close? Air-to-open or air-to- closc? Explain the reasons for your choice. (b) Should the proportional controller be direct-acting or reverse-acting for safe operation of the process? Explain your reasons for your selection. (c) The controller gain setting is Ke =2.0 If the gas surge tank pressure suddenly increases to 25 psig, calculate the controller output signal in units of mA immediately after the pressure increase.
Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
Related questions
Question
Process Dynamic and Control

Transcribed Image Text:A gas surge tank shown below is under proportional feedback control. The set point on the P-controller (PC) is
20 psig, and at steady-state the controller output signal is 12 mA. The controller output signal is sent to a
current-to-pressure transducer (KIP) in order to adjust the air-operated control valve on the exit line. The
pressure transmitter (PT) has a calibrated input range of 0-50 psip, a 4-20 mA output range and negligible time
constant.
(a) What is your recommendation for the control valve? Fail-open or fail-close? Air-to-open or air-to-
close? Explain the reasons for your choice.
(b) Should the proportional controller be direct-acting or reverse-acting for safe operation of the process?
Explain your reasons for your selection.
(c) The controller gain setting is Ke = 2.0 1If the gas surge tank pressure suddenly increases to 25 psig,
calculate the controller output signal in units of mA immediately after the pressure increase.
PT
PC
Kr
Gas Out
Gas In
Gas Surge Tank
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps

Recommended textbooks for you

Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education

Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY

Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall

Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education

Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY

Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall


Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning

Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The