b. A generating station supply two consumer I and 2 as follow: Time (Hours) Consumer 1 (kW) Consumer 2 (kW) midnight 4 a.m 50 100 4 a.m-6 p.m 180 6 p.m-8 p.m 0 8 p.m-10 p.m 10-midnight 300 250 120 0 500 Draw the daily load curve and find (i) load factor (ii) diversity factor (iii) plant use factor. 150
Q: f you haven’t used Circuits.io yet, you may refer to this brief video which shows how to build the…
A: Step 1:
Q: 1-5.5 If A and B are subsets in he same space S, find a) (AB) (B - A) b) (A-B) B c) (AB)U (ANB)…
A: a) (A - B) ∩ (B - A)A - B: The set of elements in A but not in B, i.e., A−B=A∩B̄.B - A: The set of…
Q: Find I3 in the circuit
A: Step 1: Step 2: Step 3: Step 4:
Q: Describe the signal in Figure E.49 as a ramp function minus a summation of step functions. 15 x(t)…
A: The given signal in Figure E.49 appears to be a sawtooth wave that repeats every 4 units of time. To…
Q: Energy required in the US in 1995 was 3.92*10^6 Gwh. What is the equivalent in BTU?
A: 1 GWh=3.412×109 BTU Energy in BTU=3.92×106 GWh×3.412×109 BTU/GWhEnergy in BTU=13.38544×1015…
Q: Draw the complete transformer equivalent circuit showing all component values. - (Assume the…
A: Step 1:The complete transformer equivalent circuit typically includes several components to model…
Q: R = 10 kΩ, C = 1 μF and L = 22mH. Voltage sources V2 = 3 V (DC) and V1 = 1.732 + j V (AC) with…
A: Step 1:Step 2:Step 3:Step 4:Step 5:The effect of dc source remains the same.
Q: Handwritten solution required not using chatgpt..otherwise dislike
A:
Q: Solve correct complete solutions okk
A: Steps and explanations are as follows:In case of any doubt, please let me know. Thank you.
Q: Need to find I(0), t>0 by Laplace transform. Step by step solving please.
A: Step 1: Step 2: Step 3: Step 4:
Q: Find the Fourier transform of the following signals with A = 2, wo = 5 rad/s, a = 0.5 s¹, and Do=…
A: Fourier Transforms of Given SignalsPart (a)Signal:f(t) = A cos(ω₀t - φ₀) Fourier Transform:The…
Q: Q Search 191 144 3 / 5 100% Name: AENT 3823 Series, Parallel, and Combination Resistive Circuits…
A: Step 1: Step 2: Step 3: Step 4:
Q: not use ai please
A: Step 1: Step 2: Step 3: Step 4:
Q: Weare creating a home base security system. Our current steps and goals include: -Develop…
A: After developing the communication architecture, integrating security features, and creating a power…
Q: + 12 V 1 Ix 36 V (+ 2 A 2 A + + 2 24 V 3 V3 Given that I 2, determine the following quantities: a.…
A:
Q: Pen paper solution please
A:
Q: DO NOT USE CHAT GPT OTHERWISE DOWNVOTE
A: Step 1: Step 2: Step 3: Step 4:
Q: 2.20. Express the following functions in the general form of the unit step function u(±1-10): (b)…
A: Step 1:Step 2:
Q: In Multisim (or any other circuit drawing software) design a monitoring system to detect proximity…
A: ANSWER : To design the monitoring system using Multisim (or any other…
Q: Dont use chatgpt need handwritten solution ..otherwise dislike
A: Step 1: Step 2: Step 3: Step 4:
Q: I1 1 2 2A R1 1 0 100ohmV1 2 3 2v R2 3 0 3ohmI2 2 0 5aR3 4 0 9ohmV2 4 2 3v this is a spice netlist…
A:
Q: Please show all work for a & b!!
A:
Q: design a circuit using any standard gates that drives an output from EFG using the XYZ inputs
A: Step 1: Step 2: Step 3: Step 4:
Q: by: 5. Both the current and voltage for a device are shown below. Sketch the corresponding power…
A:
Q: 1. Assume that the switch has been closed for a long period of time. What is the current through the…
A: a.)Step 1: Let R1=2kΩ; R2=12kΩ; and R3=4kΩ Step 2: To find the total resistance for the series…
Q: Problem #1 Consider the switching waveforms of the voltage and current of a resistive power switch…
A: Step 1: Analyze the diagram shown then know the formula to be used and integrate what needs to be…
Q: Please show all work for a,b, & c.
A:
Q: 1. Two gaussian random variables: X₁ and X2 are linearly tra into new variables: Y, and Y2, as given…
A: Let's give it a try. To provide precise answer, I believe further reference is necessary, but I will…
Q: 1) find Yous and Voltage at various buses. jo.25 pu jo. 25 pu m ·j0.125 pu jo. A pu m jo.2 pu jo.25…
A:
Q: Consider the Delta configured circuit calculate the current I through the 3.2 V voltage source using…
A:
Q: How can V+, V-, I2, Vo, Rin (seen by V2 when V1 = 0), and Rin (seen by V1 when V2 = 0) be found for…
A: Step 1: Step 2: Step 3: Step 4:
Q: a. The core of a three phase, 50 Hz,11000/550 V delta/star, 300 kVA, core-type transformer operates…
A: Step 1: Step 2: Step 3: Step 4:
Q: Determine the Fourier transform of the waveform below with A = 12 and T = 3 s. f(t) A 24/3 A/3- t(s)…
A:
Q: Answer True or False and correct errors if found: 1. The LC oscillator circuits are used to operate…
A: 1. The LC oscillator circuits are used to operate in low and moderate frequencies. False…
Q: 7. (5 points) Given the following circuit, find the impulse response h(t) and step response s(t) of…
A: Step 1: Step 2: Step 3: Step 4:
Q: Obtain the cosine/sine Fourier series representation for f(t) = [sin(4πt). K(1) 1/2 T
A: Step 1: f(−t)=∣sin(−4πt)∣=∣−sin(4πt)∣=∣sin(4πt)∣=f(t)Thus, f(t) is an even function, and the Fourier…
Q: 4. Using mesh current analysis, find V2 such that the source current of V₂ is zero. 1512 120 112 PPP…
A: Step 1:When source Current of v2 is zero meash 3 will become open circuit. therefore voltage of v2…
Q: Its not even last answer
A:
Q: Dont use chatgpt please do by pen paper otherwise dislike
A: Step 1:Step 2:Step 3:
Q: (c) www R₂ (d) R6 (e) w www R₁ 120 V Is 45 V w R₁ R, www R₁ w R₁ www www R₂ www R₁ = 2.5 ohm R -3…
A: (c) Series-Parallel NetworkCircuit Configuration:Series-Parallel Network: R1=2.5 ΩR1 = 2.5 \text{…
Q: How to solve this boolean expression (y'+z')*(x+z)+y
A:
Q: Pre-emphasis circuit is a __________ filter with a time-constant value of _______.
A: Pre-emphasis circuit is a high-pass filter with a time-constant value of 50 µs or 75 µs. depending…
Q: ONLY NEED HANDWRITTEN SOLUTION DO NOT USE CHAT GPT OR ANY OTHER AI
A: Step 1:Step 2: Step 3: Step 4:
Q: omework Question 2 of 2 View Policies Show Attempt History Current Attempt in Progress 2 > 0/1 : ×…
A: Step 1: Define the events.A= the event of legitimate users.B = the event of fraudulent users.M = the…
Q: question number 25
A: Step 1:
Q: A power station has to meet the following demand: Group A: 200 kW between 8 A.M. and 6 P.M. Group B:…
A:
Q: For the following figure of x(t), what is fo. Wo, and To? x(t) 4 2 -4 -2 0 2 4 -2 T=4, f=1/4, w =л/2…
A: Step 1: Step 2:
Q: ww 25 A 17 Ω ww 12 Ω 8 Ω ww 16 Ω www 10 mF ww 5 Ω 20 Ω The circuit above is in steady state at t = 0…
A: Step 1: Step 2: Step 3: Step 4:
Q: A signal occurring in a television set is illustrated in Figure E.46. Write a mathematical…
A:
Q: A signal is zero for all time before t = -2, rises linearly from 0 to 3 between t = −2 and t = 4 and…
A:
Step by step
Solved in 2 steps with 2 images
- Two generators are supplying a load. Both the generators have a no-load frequency of61.5 Hz and the slope sp of 1 MW/HZ. If they are supplying a real load of 2.0 MW at 0.8 pflagging, what would be the system frequency and power sharing between two generators?What measures can be taken to make the frequency 60 HZ. If an additional 1.0 MW load isconnected to the existing one what would the system frequency be.The peak load on a 50 MW power station is 39 MW. It supplies power through for transformers whose connected loads are 17, 12,9 and 10 MW. The maximum demands on these transformers are 15, 10, 8 and 9 MW respectively. The annual load factor is 50% and the plant is operating for 65% of the period in a year. 102. The average load on the station is (A) 50000 kW (C) 39000 kW (B) 19500 kW (D) 48000 kW. 103. The energy supplied per year is (A) 438 x 106 kWh (C) 170.82 x 106 kWh (B) 341.64 x 106 kWh (D) 420.48 x 106 kWh.two generators supplying a load. Generator I has a no-load frequency of 62.5 Hz and a slope Sp1 of I MW/Hz. Generator 2 has a no-load frequency of 62.0 Hz and a slope sp2 of I MW/Hz. The two generators are supplying a real load totaling 2.5 MW at 0.8 PF lagging. (a) At what frequency is this system operating, and how much power is supplied by each of the two generators? (b) Suppose an additional I-MW load were attached to this power system. What would the new system frequency be, and how much power would Gl and G2 supply now? Generator 1 VT V2 Generator 2 VTí KVAR KVAR
- A generating station has a maximum capacity of 100 kW and costs $300,000. The annual fixed charges are 12% of the cost of the generating station consisting of 5% interest, 5% depreciation and 2% taxes. Find the fixed charges per kWh generated if load factor is (a) 100% and (b) 25%.Two parallel loads are connected to a 120 volt rms, 60 Hz power line. One load absorbs 10 k watts at 0.8 power factor lagging. The second load absorbs 4 k watts at 0.9 power factor leading. Determine the real (watts) and reactive (VARS) power of the combined load.A 500 MVA synchronous machine has H, = 5.6 MJ/MVA and a 1200 MVA machine has H₂ = 2.0 MJ/MVA. The two machines operate in parallel in a power station. What is the equivalent. H constant for the two, relative to a 100 MVA base?
- A single-phase, 120V(rms),60Hz source supplies power to a series R-L circuit consisting of R=10 and L=40mH. (a) Determine the power factor of the circuit and state whether it is lagging or leading. (b) Determine the real and reactive power absorbed by the load. (c) Calculate the peak magnetic energy Wint stored in the inductor by using the expression Wint=L(Irms)2 and check whether the reactive power Q=Wint is satisfied. (Note: The instantaneous magnetic energy storage fluctuates between zero and the peak energy. This energy must be sent twice each cycle to the load from the source by means of reactive power flows.)Consider two interconnected voltage sources connected by a line of impedance Z=jX, as shown in Figure 2.27. (a) Obtain expressions for P12 and Q12. (b) Determine the maximum power transfer and the condition for it toFor a power station the yearly load duration curve is a straight line from 50,000 to 4000 kw. To meet the load three turbogenerators are installed. The capacity of two generators is 20,000 kw each and the 3rd is rated at 7,000 kw. a. Draw the annual load duration curve b. Determine the following the Energy generated per year, Load factor and Annual Capacity factor.
- I:59)2. a) Explain the terms load factor and diversity factor. b) Discuss the advantages of interconnected grid system. c) A generating station is to supply four regions of load whose peak loads are 10 MW, 5 MW, 8 MW and 7 MW. The diversity factor at the station is 1-5 and the average annual load factor is 60%. Calculate: (i) the maximum demand on the station, (ii) annual energy supplied by the station and (iii) suggest the installed capacity and the number of units.21. The total power drawn by two-impedance load in parallel is 15kW at 85% power factor lagging, it's being supplied by 230- volts AC source. One of the loads (Load 1) takes 11KVA at 90% power factor leading. a. What is the real power, reactive power, and the apparent power of the unknown impedance (Load 2)? b. Find the resistance and the reactance of the other impedance load (Load 2). c. Determine the currents on each branch and the total current