As a new engineer, you plan to propose a heat exchanger network design of the processing plant. After consideration of available data provided by the plant manager, the stream data extracted as in Table 4. You were measured the energy target using problem table analysis and know that this plant has threshold problem and only need 14.02 MW of hot utilities at the minimum permissible temperature difference, 10°C. Design the heat exchanger network (HEN) for the plant with given pinch temperature, 45°C. Show details calculation of feasibility for all heat exchangers involved. Stream 1 2 3 4 5 Table 4 Stream data Supply Temperature, Target Temperature, (°C) (°C) 60 300 200 70 150 230 190 50 40 280 Enthalpy, (kW) 8400 -5200 4000 -3500 10320

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
As a new engineer, you plan to propose a heat exchanger network design of the processing
plant. After consideration of available data provided by the plant manager, the stream data
extracted as in Table 4. You were measured the energy target using problem table analysis
and know that this plant has threshold problem and only need 14.02 MW of hot utilities at the
minimum permissible temperature difference, 10°C. Design the heat exchanger network
(HEN) for the plant with given pinch temperature, 45°C. Show details calculation of feasibility
for all heat exchangers involved.
Stream
1
2
3
4
5
Table 4 Stream data
Supply Temperature, Target Temperature,
(°C)
(°C)
60
300
200
150
190
40
70
230
50
280
Enthalpy,
(kW)
8400
-5200
4000
-3500
10320
Transcribed Image Text:As a new engineer, you plan to propose a heat exchanger network design of the processing plant. After consideration of available data provided by the plant manager, the stream data extracted as in Table 4. You were measured the energy target using problem table analysis and know that this plant has threshold problem and only need 14.02 MW of hot utilities at the minimum permissible temperature difference, 10°C. Design the heat exchanger network (HEN) for the plant with given pinch temperature, 45°C. Show details calculation of feasibility for all heat exchangers involved. Stream 1 2 3 4 5 Table 4 Stream data Supply Temperature, Target Temperature, (°C) (°C) 60 300 200 150 190 40 70 230 50 280 Enthalpy, (kW) 8400 -5200 4000 -3500 10320
Expert Solution
steps

Step by step

Solved in 4 steps with 16 images

Blurred answer
Similar questions
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The