An engineer has been given the following data on a conditioned room: Sensible heat gain 30 kW Latent heat gain 15 kW Supply air 18°C Outdoor air 35°C DB and 24°C WB Desired room condition 27°C DB and 50% RH For ventilation, 15% is outdoor air, the balance of air requirement being recirculated from room conditioned with some portion being by-passed around the cooling coil. There is no reheater, the desired room state is attained by the by-passing of air. It is found that the apparatus DP temperature of coil is 10°C. Find the: a. tons of refrigeration; and b. mass flow rate of the time by-passed air.
An engineer has been given the following data on a conditioned room: Sensible heat gain 30 kW Latent heat gain 15 kW Supply air 18°C Outdoor air 35°C DB and 24°C WB Desired room condition 27°C DB and 50% RH For ventilation, 15% is outdoor air, the balance of air requirement being recirculated from room conditioned with some portion being by-passed around the cooling coil. There is no reheater, the desired room state is attained by the by-passing of air. It is found that the apparatus DP temperature of coil is 10°C. Find the: a. tons of refrigeration; and b. mass flow rate of the time by-passed air.
Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
Related questions
Concept explainers
Heat Exchangers
Heat exchangers are the types of equipment that are primarily employed to transfer the thermal energy from one fluid to another, provided that one of the fluids should be at a higher thermal energy content than the other fluid.
Heat Exchanger
The heat exchanger is a combination of two words ''Heat'' and ''Exchanger''. It is a mechanical device that is used to exchange heat energy between two fluids.
Question
An engineer has been given the following data on a conditioned room:
Sensible heat gain 30 kW
Latent heat gain 15 kW
Supply air 18°C
Outdoor air 35°C DB and 24°C WB
Desired room condition 27°C DB and 50% RH
For ventilation, 15% is outdoor air, the balance of air requirement being recirculated from room conditioned with some portion being by-passed around the cooling coil. There is no reheater, the desired room state is attained by the by-passing of air. It is found that the apparatus DP temperature of coil is 10°C. Find the:
a. tons of refrigeration; and
b. mass flow rate of the time by-passed air.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps with 1 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY