A long thin-walled double-pipe heat exchanger with tube and shell diameters of 1.0 cm and 2.5 cm, respectively, is used to condense refrigerant-134a by water at 20 0C. The refrigerant flows through the tube, with a convection heat transfer coefficient of 5000 W/m2 K. Water flows through the shell at a rate of 0.3 kg/s. Determine the overall heat transfer coefficient of this heat exchanger. If a 2-mm-thick layer of limestone (k = 1.3 W/m K) forms on the outer surface of the inner tube what will be new overall heat transfer coefficient
Heat Exchangers
Heat exchangers are the types of equipment that are primarily employed to transfer the thermal energy from one fluid to another, provided that one of the fluids should be at a higher thermal energy content than the other fluid.
Heat Exchanger
The heat exchanger is a combination of two words ''Heat'' and ''Exchanger''. It is a mechanical device that is used to exchange heat energy between two fluids.
1. A long thin-walled double-pipe heat exchanger with tube and shell diameters of 1.0 cm and 2.5 cm, respectively, is used to condense refrigerant-134a by water at 20 0C. The refrigerant flows through the tube, with a convection heat transfer coefficient of 5000 W/m2 K. Water flows through the shell at a rate of 0.3 kg/s. Determine the overall heat transfer coefficient of this heat exchanger. If a 2-mm-thick layer of limestone (k = 1.3 W/m K) forms on the outer surface of the inner tube what will be new overall heat transfer coefficient
Trending now
This is a popular solution!
Step by step
Solved in 7 steps with 7 images