A line is recorded as 472.90m long using a 30m tape. During measurement, the temperature is 32°C and the tape is laid on the ground under a 75N pull. The tape has the following properties: weight of 0.065kg/m, young modulus of elasticity is 200GPA, cross sectional area of the tape is 3mm? and the coefficient of linear expansion is 0.0000116/"C. The tape is 30.005m long at 40°C under a 20ON pull supported at both ends. Assume the standard pull is 50N, compute: a. The standard temperature in °C. b. The actual length of tape during measurement in meter. c. The true distance of the line in meter. If the survey are to be connected to the national mapping system of a country, the distances will need to be reduced to the common datum of the system, namely MSL (Mean Sea Level). The adjustment is expressed as H Reduction Factor = 1 R L' = L(1 d. If the height of measurement from the Mean Sea Level is 12km, determine the adjusted distance in meter.

Steel Design (Activate Learning with these NEW titles from Engineering!)
6th Edition
ISBN:9781337094740
Author:Segui, William T.
Publisher:Segui, William T.
Chapter1: Introduction
Section: Chapter Questions
Problem 1.5.5P: The results of a tensile test are shown in Table 1.5.2. The test was performed on a metal specimen...
icon
Related questions
Question

Need it asap please answer this, thankyou.

A line is recorded as 472.90m long using a 30m tape. During measurement, the temperature is 32°C and
the tape is laid on the ground under a 75N pull. The tape has the following properties: weight of
0.065kg/m, young modulus of elasticity is 200GPA, cross sectional area of the tape is 3mm? and the
coefficient of linear expansion is 0.0000116/°C. The tape is 30.005m long at 40°C under a 200N pull
supported at both ends. Assume the standard pull is 50N, compute:
a. The standard temperature in °C.
b. The actual length of tape during measurement in meter.
c. The true distance of the line in meter.
If the survey are to be connected to the national mapping system of a country, the distances will need to
be reduced to the common datum of the system, namely MSL (Mean Sea Level). The adjustment is
expressed as
L' = L(1
RA
H
Reduction Factor = 1 –
R
d. If the height of measurement from the Mean Sea Level is 12km, determine the adjusted
distance in meter.
Transcribed Image Text:A line is recorded as 472.90m long using a 30m tape. During measurement, the temperature is 32°C and the tape is laid on the ground under a 75N pull. The tape has the following properties: weight of 0.065kg/m, young modulus of elasticity is 200GPA, cross sectional area of the tape is 3mm? and the coefficient of linear expansion is 0.0000116/°C. The tape is 30.005m long at 40°C under a 200N pull supported at both ends. Assume the standard pull is 50N, compute: a. The standard temperature in °C. b. The actual length of tape during measurement in meter. c. The true distance of the line in meter. If the survey are to be connected to the national mapping system of a country, the distances will need to be reduced to the common datum of the system, namely MSL (Mean Sea Level). The adjustment is expressed as L' = L(1 RA H Reduction Factor = 1 – R d. If the height of measurement from the Mean Sea Level is 12km, determine the adjusted distance in meter.
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Work breakdown structure
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.