A 3-phase, 2000 hp, 2300 V, 50 1lz, 6 pole salient pole synchronous motor has X,-1.95 /phase and X,-1.4 2/phase. The motor operates at full load and 0.8 power factor leading. 14. The quadrature-axis current 1, is: b) 247 A a) 440 A 276 A d) 464 A 15. The direct-axis current I, is: a) 159.6 A O377.8 A c) 61.7 A d) 397.6 A 16. The excitation voltage E, is: b) 1598 V a) 2025 V c) 1279 V 2007 V 17. The developed power due to field excitation is: a) 951 kW b) 1278 kW © 1195 kW d) 1495 kW 18. The developed reluctance power is: a) 397 kW b) 455 kW c) 360 kW 297 kW

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Electrical machine
A 3-phase, 2000 hp, 2300 V, 50 HIz, 6 pole salient pole synchronous motor has X, - 1.95 /phase
and X, 1. 4 2/phase. The motor operates at full load and 0.8 power factor leading.
14. The quadrature-axis current 1, is:
a) 440 A
b) 247 A
276 A
d) 464 A
15. The direct-axis current I, is:
O377.8 A
a) 159.6 A
c) 61.7 A
d) 397.6 A
16. The excitation voltage E, is:
b) 1598 V
a) 2025 V
c) 1279 V
2007 V
17. The developed power due to field excitation is:
a) 951 kW
b) 1278 kW
© 1195 kW
d) 1495 kW
18. The developed reluctance power is:
a) 397 kW
b) 455 kW
c) 360 kW
297 kW
Transcribed Image Text:A 3-phase, 2000 hp, 2300 V, 50 HIz, 6 pole salient pole synchronous motor has X, - 1.95 /phase and X, 1. 4 2/phase. The motor operates at full load and 0.8 power factor leading. 14. The quadrature-axis current 1, is: a) 440 A b) 247 A 276 A d) 464 A 15. The direct-axis current I, is: O377.8 A a) 159.6 A c) 61.7 A d) 397.6 A 16. The excitation voltage E, is: b) 1598 V a) 2025 V c) 1279 V 2007 V 17. The developed power due to field excitation is: a) 951 kW b) 1278 kW © 1195 kW d) 1495 kW 18. The developed reluctance power is: a) 397 kW b) 455 kW c) 360 kW 297 kW
Expert Solution
steps

Step by step

Solved in 5 steps with 4 images

Blurred answer
Knowledge Booster
Gear motor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,