A 200 MVA, 25 kV, cylindrical rotor, synchronous generator has a saturated synchronous reactance of 1.5 pu. a) What internal excitation is required to deliver 1½ rated load at 0.8 pf lagging at rated terminal While calculating this professor first said 200MVA and 25KVA are 1pu because they are rated values. Then he easily find the E filed by Efiled = Vterminal + Armature Current*total impedance (synchronous reactance in this case) However, I am confused about this solution. He didn't calculate the Vphase he directly said Vterminal is equal to 1pu. Shouldn't we need to say Vterminal = 1/sqr(3) pu rather than 1 for this question?

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
100%
A 200 MVA, 25 kV, cylindrical rotor, synchronous generator has a saturated synchronous
reactance of 1.5 pu.
a) What internal excitation is required to deliver 1½ rated load at 0.8 pf lagging at rated terminal
While calculating this professor first said 200MVA and 25KVA are 1pu because they are rated
values. Then he easily find the E filed by Efiled = Vterminal + Armature Current*total
impedance (synchronous reactance in this case)
However, I am confused about this solution.
He didn't calculate the Vphase he directly said Vterminal is equal to 1pu.
Shouldn't we need to say Vterminal = 1/sqr(3) pu rather than 1 for this question?
Transcribed Image Text:A 200 MVA, 25 kV, cylindrical rotor, synchronous generator has a saturated synchronous reactance of 1.5 pu. a) What internal excitation is required to deliver 1½ rated load at 0.8 pf lagging at rated terminal While calculating this professor first said 200MVA and 25KVA are 1pu because they are rated values. Then he easily find the E filed by Efiled = Vterminal + Armature Current*total impedance (synchronous reactance in this case) However, I am confused about this solution. He didn't calculate the Vphase he directly said Vterminal is equal to 1pu. Shouldn't we need to say Vterminal = 1/sqr(3) pu rather than 1 for this question?
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,