A: A synchronous generator of supplies a motor of 50 MVA, 22 kV, and 0.2 pu transient reactance. The motor is drawing 40 MW at 0.8 power factor leading and terminal voltage of 21 9 kV. The line connecting them has a reactance of 0.05 pu on a base of 100 MVA. Find the transient currents in the generator, the motor, and the fault when a 3-ph fault occurs at the motor terminals Take Sa = 100 MVA, Vis = 22 kV, and use the internal voltages of the machines method.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter7: Symmetrical Faults
Section: Chapter Questions
Problem 7.3MCQ: The amplitude of the sinusoidal symmetrical ac component of the three-phase short-circuit current of...
icon
Related questions
Question
A: A synchronous generator of 100 MVA, 22 kV, and 0.25 pu transient reactance
supplies a motor of 50 MVA, 22 kV, and 0.2 pu transicnt reactance. The motor is
drawing 40 MW at 0.8 power factor leading and terminal voltage of 21 9 kV. The
line connecting them has a reactance of 0,05 pu on a base of 100 MVA. Find the
transient currents in the generator, the motor, and the fault when a 3-ph fault occurs at
the motor termınals Take Sa 100 MVA, V = 22 kV, and use the internal voltages
of the machines method.
(1-2)
Transcribed Image Text:A: A synchronous generator of 100 MVA, 22 kV, and 0.25 pu transient reactance supplies a motor of 50 MVA, 22 kV, and 0.2 pu transicnt reactance. The motor is drawing 40 MW at 0.8 power factor leading and terminal voltage of 21 9 kV. The line connecting them has a reactance of 0,05 pu on a base of 100 MVA. Find the transient currents in the generator, the motor, and the fault when a 3-ph fault occurs at the motor termınals Take Sa 100 MVA, V = 22 kV, and use the internal voltages of the machines method. (1-2)
Expert Solution
steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Synchronous Generator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning