9. Imagine that you need to separate a mixture that contains the components given in the table below. You decide to separate the components by capillary zone electrophoresis in an untreated capillary with the injection done at the positive end of the capillary and the detector is at the negative end. What is the elution order of the components? Explain why the components come out in this order. Analyte Charge Radius (A) 1 2 3 4 5 6 7 +1 -2 0 -1 0 +1 +3 1.0 5.0 10.0 3.0 25.0 3.0 2.5 The cationic analyte with an eletrophoretic mobility of 4.31 x 10 cm² s¹ V¹was separated by CE in
9. Imagine that you need to separate a mixture that contains the components given in the table below. You decide to separate the components by capillary zone electrophoresis in an untreated capillary with the injection done at the positive end of the capillary and the detector is at the negative end. What is the elution order of the components? Explain why the components come out in this order. Analyte Charge Radius (A) 1 2 3 4 5 6 7 +1 -2 0 -1 0 +1 +3 1.0 5.0 10.0 3.0 25.0 3.0 2.5 The cationic analyte with an eletrophoretic mobility of 4.31 x 10 cm² s¹ V¹was separated by CE in
Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
Related questions
Question

Transcribed Image Text:9. Imagine that you need to separate a mixture that contains the components given in the table below. You
decide to separate the components by capillary zone electrophoresis in an untreated capillary with the
injection done at the positive end of the capillary and the detector is at the negative end. What is the
elution order of the components? Explain why the components come out in this order.
Analyte
Charge
Radius (A)
1
2
3
4
5
6
7
+1
-2
0
-1
0
+1
+3
1.0
5.0
10.0
3.0
25.0
3.0
2.5
The cationic analyte with an eletrophoretic mobility of 4.31 x 10 cm²s¹ V¹was separated by
CE in a
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps

Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Recommended textbooks for you

Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning

Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education

Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning

Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning

Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education

Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning

Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education

Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning

Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY