9. Imagine that you need to separate a mixture that contains the components given in the table below. You decide to separate the components by capillary zone electrophoresis in an untreated capillary with the injection done at the positive end of the capillary and the detector is at the negative end. What is the elution order of the components? Explain why the components come out in this order. Analyte Charge Radius (A) 1 2 3 4 5 6 7 +1 -2 0 -1 0 +1 +3 1.0 5.0 10.0 3.0 25.0 3.0 2.5 The cationic analyte with an eletrophoretic mobility of 4.31 x 10 cm² s¹ V¹was separated by CE in

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question
9. Imagine that you need to separate a mixture that contains the components given in the table below. You
decide to separate the components by capillary zone electrophoresis in an untreated capillary with the
injection done at the positive end of the capillary and the detector is at the negative end. What is the
elution order of the components? Explain why the components come out in this order.
Analyte
Charge
Radius (A)
1
2
3
4
5
6
7
+1
-2
0
-1
0
+1
+3
1.0
5.0
10.0
3.0
25.0
3.0
2.5
The cationic analyte with an eletrophoretic mobility of 4.31 x 10 cm²s¹ V¹was separated by
CE in a
Transcribed Image Text:9. Imagine that you need to separate a mixture that contains the components given in the table below. You decide to separate the components by capillary zone electrophoresis in an untreated capillary with the injection done at the positive end of the capillary and the detector is at the negative end. What is the elution order of the components? Explain why the components come out in this order. Analyte Charge Radius (A) 1 2 3 4 5 6 7 +1 -2 0 -1 0 +1 +3 1.0 5.0 10.0 3.0 25.0 3.0 2.5 The cationic analyte with an eletrophoretic mobility of 4.31 x 10 cm²s¹ V¹was separated by CE in a
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Analytical Separations
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY