9- Suggest that you are an electrical power engineer with the Iraqi National Grid (ING ), you need to protect a power transformer of 132 KV / 11 KV against overvoltage, if the electrical discharge breakdown field strength = 90 MV / m and the distance between the electrodes 1 Cm, and the BIL = 630 KV, the rate of rise of waveform of overvoltage = 900 KV/S. Find the allowable worst location of the Surge .Diverter a- The allowable worst location of the Surge Diverter at : 33.5 m. b-) All these answers are wrong. C- The allowable worst location of the Surge Diverter at: 28.33 m. d- The allowable worst location of the Surge Diverter at : 30 m. %3D %3D

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
9- Suggest that you are an electrical power engineer with the Iraqi National Grid (ING ),
you need to protect a power transformer of 132 KV / 11 KV against overvoltage, if
the electrical discharge breakdown field strength = 90 Mv /m and the distance
between the electrodes 1 Cm , and the BIL = 630 KV, the rate of rise of waveform of
overvoltage = 900 KV/S. Find the allowable worst location of the Surge .Diverter
a- The allowable worst location of the Surge Diverter at : 33.5 m.
b-) All these answers are wrong.
C- The allowable worst location of the Surge Diverter at : 28.33 m.
d- The allowable worst location of the Surge Diverter at: 30 m. >
10- Suppose that there are two types of H.V.T.Ls operating at the same voltage and
carrying the same current, but one of them with a smooth shape while the other
with standard shape. ? Which of them, you will choose.
a- Choosing the standard one.
b- Choosing the one with hollow construction shape.
C- All these answers are wrong.
d- Choosing the smooth one.
11- From the general electrostatic theories , the field strength at: breakdown is given by
a Eb = V/do = 0.6 [Y/(Eo Er)] 0.05.
b- Eb V/do = 0.6 [Y/(€o/Er)] 0.5.
C- Eb = V/ do = 0.6 [ Y/(€o Er) 30.5.
Eb V/ do =a.6[Y/(60 Er)10.5.
12- The peak inverse voltage across any diode under no load condition in DC - HV Half -
Bridge : rectifier is
a- 1 Vo.
b- 0.8 Vo.
C2V0.
d- 1.8 V.
13- The main factor in studying High voltage engineering techniques is:
a- Voltage.
b- Current .
C- Electric Field.
d- Frequency.
14- Power loss due to corona is :
a- Inversely proportional to frequency.
b- Proportional to frequency.
Frequency does not effect. .
d- All these answers are wrong.
C-
15- As the ambient temperature increase the disruptive critical voltage of corona is:
a Decreased.
b- Increased.
C- No effect .
d- All these answers are wrong.
16- Using HV underground cable improve voltage profile and power factor in any loaded
inductive electrical grid because
a- due to its reactive power effect.
b- Due to resistive effect.
C- Due to its capacitive power effect.
d- All of the above answers are wrong.
Transcribed Image Text:9- Suggest that you are an electrical power engineer with the Iraqi National Grid (ING ), you need to protect a power transformer of 132 KV / 11 KV against overvoltage, if the electrical discharge breakdown field strength = 90 Mv /m and the distance between the electrodes 1 Cm , and the BIL = 630 KV, the rate of rise of waveform of overvoltage = 900 KV/S. Find the allowable worst location of the Surge .Diverter a- The allowable worst location of the Surge Diverter at : 33.5 m. b-) All these answers are wrong. C- The allowable worst location of the Surge Diverter at : 28.33 m. d- The allowable worst location of the Surge Diverter at: 30 m. > 10- Suppose that there are two types of H.V.T.Ls operating at the same voltage and carrying the same current, but one of them with a smooth shape while the other with standard shape. ? Which of them, you will choose. a- Choosing the standard one. b- Choosing the one with hollow construction shape. C- All these answers are wrong. d- Choosing the smooth one. 11- From the general electrostatic theories , the field strength at: breakdown is given by a Eb = V/do = 0.6 [Y/(Eo Er)] 0.05. b- Eb V/do = 0.6 [Y/(€o/Er)] 0.5. C- Eb = V/ do = 0.6 [ Y/(€o Er) 30.5. Eb V/ do =a.6[Y/(60 Er)10.5. 12- The peak inverse voltage across any diode under no load condition in DC - HV Half - Bridge : rectifier is a- 1 Vo. b- 0.8 Vo. C2V0. d- 1.8 V. 13- The main factor in studying High voltage engineering techniques is: a- Voltage. b- Current . C- Electric Field. d- Frequency. 14- Power loss due to corona is : a- Inversely proportional to frequency. b- Proportional to frequency. Frequency does not effect. . d- All these answers are wrong. C- 15- As the ambient temperature increase the disruptive critical voltage of corona is: a Decreased. b- Increased. C- No effect . d- All these answers are wrong. 16- Using HV underground cable improve voltage profile and power factor in any loaded inductive electrical grid because a- due to its reactive power effect. b- Due to resistive effect. C- Due to its capacitive power effect. d- All of the above answers are wrong.
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Stability Analysis in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,