83. The power input to a 6 pole, 3 phase, 50 Hz induction motor is 42 KW; the speed is 970 rpm. The stator are 1.2 KW and the friction and windage losses are 1.8 KW. Find (i) the slip (ii) the rotor copper loss (iii) B.H.P (iv) the efficiency.

Delmar's Standard Textbook Of Electricity
7th Edition
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Stephen L. Herman
Chapter32: Three-phase Motors
Section: Chapter Questions
Problem 6RQ: Name three factors that determine the torque produced by an induction motor.
icon
Related questions
Question
83. The power input to a 6 pole, 3 phase, 50 Hz induction motor is 42 KW; the speed is 970
rpm. The stator are 1.2 KW and the friction and windage losses are 1.8 KW. Find (i) the slip (ii)
the rotor copper loss (iii) B.H.P (iv) the efficiency.
Transcribed Image Text:83. The power input to a 6 pole, 3 phase, 50 Hz induction motor is 42 KW; the speed is 970 rpm. The stator are 1.2 KW and the friction and windage losses are 1.8 KW. Find (i) the slip (ii) the rotor copper loss (iii) B.H.P (iv) the efficiency.
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Three phase Induction Motor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning