7. A source of 100 Volts rms is supplying a resistance 80 ohms in parallel with a 200mH inductor. To what angle is the current lag or lead? A. 46.7 deg. lag B. 43.3 deg. lag C. 46.7 deg. lead D. 43.3 deg. Lead

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
7. A source of 100 Volts rms is supplying a resistance 80 ohms in parallel with a 200mH
inductor. To what angle is the current lag or lead?
A. 46.7 deg. lag
B. 43.3 deg. lag
C. 46.7 deg. lead
D. 43.3 deg. Lead
8. Two impedances Zı=2+j4 and Z2=R+j0, are connected in parallel. Determine R so that the pf
of the circuit is 0.9 lagging.
A. 3.2 ohms
B. 4.2 ohms
C. 2.4 ohms
D. 6.4 ohms
9. The power factor of a load on a 120 volt. 60HZ source is raised from 0.707 to 0.866 lagging
by connecting a 53 micro-farad capacitor across the load. What is the true power of the load in
watts?
C. 862
D. 268
А. 286
В. 682
10. A factory has an average demand of 176 kw at 70% power factor. What is the minimum size
of capacitor required to raise the power factor to 95%?
C. 122 KVAR
D. 157 KVAR
A. 165 KVAR
B. 82 KVAR
Transcribed Image Text:7. A source of 100 Volts rms is supplying a resistance 80 ohms in parallel with a 200mH inductor. To what angle is the current lag or lead? A. 46.7 deg. lag B. 43.3 deg. lag C. 46.7 deg. lead D. 43.3 deg. Lead 8. Two impedances Zı=2+j4 and Z2=R+j0, are connected in parallel. Determine R so that the pf of the circuit is 0.9 lagging. A. 3.2 ohms B. 4.2 ohms C. 2.4 ohms D. 6.4 ohms 9. The power factor of a load on a 120 volt. 60HZ source is raised from 0.707 to 0.866 lagging by connecting a 53 micro-farad capacitor across the load. What is the true power of the load in watts? C. 862 D. 268 А. 286 В. 682 10. A factory has an average demand of 176 kw at 70% power factor. What is the minimum size of capacitor required to raise the power factor to 95%? C. 122 KVAR D. 157 KVAR A. 165 KVAR B. 82 KVAR
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Sinusoids and phasors
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,