6.4 The following test results are obtained for a 30, 25 kV, 750 MVA, 60 Hz, 3600 rpm, star-connected synchronous machine at rated speed. It (A) 1500 VLL (kV) open-circuit test 25 I. (A) short-circuit test 10,000 VLL (KV) air gap line 30 (a) Determine the number of poles of the synchronous machine. (b) Determine the unsaturated and saturated values of the synchronous reactance in ohms and per unit. (c) The short-circuit test is performed at constant field current (1500 A) but at different speeds- 1000 rpm, 2000 rpm, 3000 rpm, and 3600 rpm. Determine the short-circuit current at these speeds. (d) Determine the field current if the synchronous machine delivers rated MVA to an infinite bus at 0.9 lagging power factor.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question

Please help with explanation for each stage

6.4
The following test results are obtained for a 30, 25 kV, 750 MVA, 60 Hz, 3600 rpm, star-connected
synchronous
machine at rated speed.
It (A)
1500
VLL (KV)
open-circuit test
25
I. (A)
short-circuit test
10,000
VLL (KV)
air gap line
30
(a) Determine the number of poles of the synchronous machine.
(b) Determine the unsaturated and saturated values of the synchronous reactance in ohms and
per unit.
mi
(c) The short-circuit test is performed at constant field current (1500 A) but at different speeds-
1000 rpm, 2000 rpm, 3000 rpm, and 3600 rpm. Determine the short-circuit current at these
speeds.
(d) Determine the field current if the synchronous machine delivers rated MVA to an infinite bus
at 0.9 lagging power factor.
Тг
Transcribed Image Text:6.4 The following test results are obtained for a 30, 25 kV, 750 MVA, 60 Hz, 3600 rpm, star-connected synchronous machine at rated speed. It (A) 1500 VLL (KV) open-circuit test 25 I. (A) short-circuit test 10,000 VLL (KV) air gap line 30 (a) Determine the number of poles of the synchronous machine. (b) Determine the unsaturated and saturated values of the synchronous reactance in ohms and per unit. mi (c) The short-circuit test is performed at constant field current (1500 A) but at different speeds- 1000 rpm, 2000 rpm, 3000 rpm, and 3600 rpm. Determine the short-circuit current at these speeds. (d) Determine the field current if the synchronous machine delivers rated MVA to an infinite bus at 0.9 lagging power factor. Тг
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Synchronous Generator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,