5-8. Refer to the following floor framing plan shown in Figure 5-18 and the following assumptions: I G-2 I G-2 I B-1 B-2 B-2 B-1 -C-1 ∙H+ 30-0 30-0" FIGURE 5-18 Floor framing plan for Exercise 5-8 4@7'-0"=28'-0" 4@7'-0"=28'-0" C-1 is a W8 x 31; Steel is ASTM A992 Grade 50 • Column unbraced length is 15-0"; K=1.0 • Floor dead load is 72 psf (includes self-weight) • Ignore connection eccentricities Determine the following: a. Design axial compressive strength, in kips, for C-1. b. The design service live load capacity of the floor in psf based on the axial strength of C-1. c. Using the live load table in ASCE 7 assign a possible occupancy type based on part (b).

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
100%
5-8. Refer to the following floor framing plan shown in Figure 5-18 and the following
assumptions:
I
G-2
I
G-2
I
B-1
B-2
B-2
B-1
-C-1
∙H+
30-0
30-0"
FIGURE 5-18 Floor framing plan for Exercise 5-8
4@7'-0"=28'-0"
4@7'-0"=28'-0"
C-1 is a W8 x 31; Steel is ASTM A992 Grade 50
• Column unbraced length is 15-0"; K=1.0
• Floor dead load is 72 psf (includes self-weight)
• Ignore connection eccentricities
Determine the following:
a. Design axial compressive strength, in kips, for C-1.
b. The design service live load capacity of the floor in psf based on the axial strength
of C-1.
c. Using the live load table in ASCE 7 assign a possible occupancy type based on part (b).
Transcribed Image Text:5-8. Refer to the following floor framing plan shown in Figure 5-18 and the following assumptions: I G-2 I G-2 I B-1 B-2 B-2 B-1 -C-1 ∙H+ 30-0 30-0" FIGURE 5-18 Floor framing plan for Exercise 5-8 4@7'-0"=28'-0" 4@7'-0"=28'-0" C-1 is a W8 x 31; Steel is ASTM A992 Grade 50 • Column unbraced length is 15-0"; K=1.0 • Floor dead load is 72 psf (includes self-weight) • Ignore connection eccentricities Determine the following: a. Design axial compressive strength, in kips, for C-1. b. The design service live load capacity of the floor in psf based on the axial strength of C-1. c. Using the live load table in ASCE 7 assign a possible occupancy type based on part (b).
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Millwork and cabinet technology
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning