5'-3" foto e. a. (a1 b (b.1 | 2. 3. SECOND FLOOR TOTAL AREA: 831 sq. ft. HATCH LEGEND: PROVIDE CONTINUOUS OSB SHEAR PANELS AT ALL EXTERIOR WALLS. PROVIDE ADEQUATE FASTENING PER CODE. PROVIDE CONTINUOUS GWB SHEAR PANELS. INSTALL VERTICALLY. PROVIDE ADEQUATE FASTENING PER CODE. GENERAL NOTES: 1. ALL INTERIOR AND EXTERIOR BALCONIES TO HAVE A 42" RAILING SYSTEM PER CODE AND TO BE COMPLIANT WITH THE AUTHORITY HAVING JURISDICTION 2. SEE STRUCTURAL ENGINEERING FOR ALL COLUMNS AND BEAM SIZES, CONNECTIONS, AND CALCULATIONS. 3. ALL STAIRS TO BE CONSTRUCTED SUCH THAT THE RISE NOR RUN OF ANY STEP EXCEEDS THE ALLOWABLE MAXIMUM PER CODE. ALL STAIRS TO HAVE CODE COMPLIANT HANDRAILS. H KEYED NOTES: 1. 42" PONY WALL, CAP FLUSH WITH 18 COUNTERTOP, PROVIDE CABINETS BELOW. 2. EXTENT OF LOFT ABOVE. 3. 54' PONY WALL, PROVIDE HOOKS AT MUDROOM SIDE AND HANDRAIL AT STAIR SIDE. 4. PROVIDE 24" DEEP COUNTERTOP, INSTALL AT 36 A.F.F. INSTALL CABINETS ABOVE AT 56 A.F.F. AND BELOW COUNTER AT FINISHED FLOOR. 5. INSTALL HOOD AND NECESSARY CONNECTIONS OVER RANGE. 6. PROVIDE BEAM POCKET FOR GLB WITH (4) 2 X 6 CONTINUOUS STUDS BELOW. 7. #1 DFL 6 X 6 ECCQ AT TOP. PROVIDE GIRDER CONNECTION PER ATTACHED DETAIL -3'-6" 13 12. 11. 3.1 -3'-6"- -2-10- 9-11- 4. -"11-י7– -7-10"- 6-8" -7-9" 48" x 24" -2-4" -5-1" MUDROOM CLG. HEIGHT: 8-1" 11-2x 7-6 6. -7-4" -3-3- mechanical chase -2-4"- LINEN 3-0 x 3-0 -3'-6"- 2-0×6-0 -13- -11-8" ° DISHWASHER REFRIDGERATOR LAUNDRY 3'-0"x3-0° 1/2 BATH CLG. HEIGHT: 8-1 8-8" x 6-2" -10'-8" LIVING AREA VAULTED CLG. (16'-3' to 11'-1') 25'-0" x 11'-6" MEDIA NICHE 2-6x6-8 -3-4" -7- -3'-6"- 2-0x6-8 -5'-9"- 6-0' x 6-8 S.G.D. KITCHEN CLG. HEIGHT: 8-1" 150 x 11-6 −12'-6"- COVERED DECK DINING AREA VAULTED CLG. (16-3" to 11'-1') 9-6' x 8-6 -4-10"- PANTRY 2-6' x 6-8 -3-10"- 96' x 24 8 —11'-7"— -4"-10"- -11-8 d. b

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter37: Air Distribution And Balance
Section: Chapter Questions
Problem 12RQ: Name four materials used to manufacture duct.
icon
Related questions
Question
100%

Calculate the running feet of exposed wall for the rooms on the given plan sheet 

list the room dimmensions

ceiling height

and exposure direcction

5'-3"
foto
e.
a.
(a1
b
(b.1
|
2.
3.
SECOND FLOOR TOTAL AREA: 831 sq. ft.
HATCH LEGEND:
PROVIDE CONTINUOUS OSB SHEAR
PANELS AT ALL EXTERIOR WALLS.
PROVIDE ADEQUATE FASTENING
PER CODE.
PROVIDE CONTINUOUS GWB
SHEAR PANELS. INSTALL
VERTICALLY. PROVIDE ADEQUATE
FASTENING PER CODE.
GENERAL NOTES:
1. ALL INTERIOR AND EXTERIOR
BALCONIES TO HAVE A 42" RAILING
SYSTEM PER CODE AND TO BE
COMPLIANT WITH THE AUTHORITY
HAVING JURISDICTION
2. SEE STRUCTURAL ENGINEERING
FOR ALL COLUMNS AND BEAM SIZES,
CONNECTIONS, AND CALCULATIONS.
3. ALL STAIRS TO BE CONSTRUCTED
SUCH THAT THE RISE NOR RUN OF ANY
STEP EXCEEDS THE ALLOWABLE
MAXIMUM PER CODE. ALL STAIRS TO
HAVE CODE COMPLIANT HANDRAILS.
H
KEYED NOTES:
1. 42" PONY WALL, CAP FLUSH WITH
18 COUNTERTOP, PROVIDE CABINETS
BELOW.
2. EXTENT OF LOFT ABOVE.
3. 54' PONY WALL, PROVIDE HOOKS AT
MUDROOM SIDE AND HANDRAIL AT
STAIR SIDE.
4. PROVIDE 24" DEEP COUNTERTOP,
INSTALL AT 36 A.F.F. INSTALL
CABINETS ABOVE AT 56 A.F.F. AND
BELOW COUNTER AT FINISHED FLOOR.
5. INSTALL HOOD AND NECESSARY
CONNECTIONS OVER RANGE.
6. PROVIDE BEAM POCKET FOR GLB
WITH (4) 2 X 6 CONTINUOUS STUDS
BELOW.
7. #1 DFL 6 X 6 ECCQ AT TOP. PROVIDE
GIRDER CONNECTION PER ATTACHED
DETAIL
-3'-6"
13
12.
11.
3.1
-3'-6"-
-2-10-
9-11-
4.
-"11-י7–
-7-10"-
6-8"
-7-9"
48" x 24"
-2-4"
-5-1"
MUDROOM
CLG. HEIGHT: 8-1"
11-2x 7-6
6.
-7-4"
-3-3-
mechanical
chase
-2-4"-
LINEN
3-0 x 3-0
-3'-6"-
2-0×6-0
-13-
-11-8"
°
DISHWASHER
REFRIDGERATOR
LAUNDRY
3'-0"x3-0°
1/2 BATH
CLG. HEIGHT: 8-1
8-8" x 6-2"
-10'-8"
LIVING AREA
VAULTED CLG. (16'-3' to 11'-1')
25'-0" x 11'-6"
MEDIA NICHE
2-6x6-8
-3-4"
-7-
-3'-6"-
2-0x6-8
-5'-9"-
6-0' x 6-8 S.G.D.
KITCHEN
CLG. HEIGHT: 8-1"
150 x 11-6
−12'-6"-
COVERED DECK
DINING AREA
VAULTED CLG. (16-3" to 11'-1')
9-6' x 8-6
-4-10"-
PANTRY
2-6' x 6-8
-3-10"-
96' x 24
8
—11'-7"—
-4"-10"-
-11-8
d.
b
Transcribed Image Text:5'-3" foto e. a. (a1 b (b.1 | 2. 3. SECOND FLOOR TOTAL AREA: 831 sq. ft. HATCH LEGEND: PROVIDE CONTINUOUS OSB SHEAR PANELS AT ALL EXTERIOR WALLS. PROVIDE ADEQUATE FASTENING PER CODE. PROVIDE CONTINUOUS GWB SHEAR PANELS. INSTALL VERTICALLY. PROVIDE ADEQUATE FASTENING PER CODE. GENERAL NOTES: 1. ALL INTERIOR AND EXTERIOR BALCONIES TO HAVE A 42" RAILING SYSTEM PER CODE AND TO BE COMPLIANT WITH THE AUTHORITY HAVING JURISDICTION 2. SEE STRUCTURAL ENGINEERING FOR ALL COLUMNS AND BEAM SIZES, CONNECTIONS, AND CALCULATIONS. 3. ALL STAIRS TO BE CONSTRUCTED SUCH THAT THE RISE NOR RUN OF ANY STEP EXCEEDS THE ALLOWABLE MAXIMUM PER CODE. ALL STAIRS TO HAVE CODE COMPLIANT HANDRAILS. H KEYED NOTES: 1. 42" PONY WALL, CAP FLUSH WITH 18 COUNTERTOP, PROVIDE CABINETS BELOW. 2. EXTENT OF LOFT ABOVE. 3. 54' PONY WALL, PROVIDE HOOKS AT MUDROOM SIDE AND HANDRAIL AT STAIR SIDE. 4. PROVIDE 24" DEEP COUNTERTOP, INSTALL AT 36 A.F.F. INSTALL CABINETS ABOVE AT 56 A.F.F. AND BELOW COUNTER AT FINISHED FLOOR. 5. INSTALL HOOD AND NECESSARY CONNECTIONS OVER RANGE. 6. PROVIDE BEAM POCKET FOR GLB WITH (4) 2 X 6 CONTINUOUS STUDS BELOW. 7. #1 DFL 6 X 6 ECCQ AT TOP. PROVIDE GIRDER CONNECTION PER ATTACHED DETAIL -3'-6" 13 12. 11. 3.1 -3'-6"- -2-10- 9-11- 4. -"11-י7– -7-10"- 6-8" -7-9" 48" x 24" -2-4" -5-1" MUDROOM CLG. HEIGHT: 8-1" 11-2x 7-6 6. -7-4" -3-3- mechanical chase -2-4"- LINEN 3-0 x 3-0 -3'-6"- 2-0×6-0 -13- -11-8" ° DISHWASHER REFRIDGERATOR LAUNDRY 3'-0"x3-0° 1/2 BATH CLG. HEIGHT: 8-1 8-8" x 6-2" -10'-8" LIVING AREA VAULTED CLG. (16'-3' to 11'-1') 25'-0" x 11'-6" MEDIA NICHE 2-6x6-8 -3-4" -7- -3'-6"- 2-0x6-8 -5'-9"- 6-0' x 6-8 S.G.D. KITCHEN CLG. HEIGHT: 8-1" 150 x 11-6 −12'-6"- COVERED DECK DINING AREA VAULTED CLG. (16-3" to 11'-1') 9-6' x 8-6 -4-10"- PANTRY 2-6' x 6-8 -3-10"- 96' x 24 8 —11'-7"— -4"-10"- -11-8 d. b
Expert Solution
steps

Step by step

Solved in 2 steps with 3 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning
Precision Machining Technology (MindTap Course Li…
Precision Machining Technology (MindTap Course Li…
Mechanical Engineering
ISBN:
9781285444543
Author:
Peter J. Hoffman, Eric S. Hopewell, Brian Janes
Publisher:
Cengage Learning
Automotive Technology: A Systems Approach (MindTa…
Automotive Technology: A Systems Approach (MindTa…
Mechanical Engineering
ISBN:
9781133612315
Author:
Jack Erjavec, Rob Thompson
Publisher:
Cengage Learning