40gal/min of water is pumped and the energy loss in the discharge line is 13.5 feet and in the suction line it is 2.5 feet. If the steel suction pipe is 2.5” in diameter and the steel discharge pipe is 1.5” in diameter. The pressure in the distribution tank is 30 psi. Determine a) the pressure at the pump outlet b) the power in kW of the pump.
40gal/min of water is pumped and the energy loss in the discharge line is 13.5 feet and in the suction line it is 2.5 feet. If the steel suction pipe is 2.5” in diameter and the steel discharge pipe is 1.5” in diameter. The pressure in the distribution tank is 30 psi. Determine a) the pressure at the pump outlet b) the power in kW of the pump.
Residential Construction Academy: House Wiring (MindTap Course List)
5th Edition
ISBN:9781337402415
Author:Gregory W Fletcher
Publisher:Gregory W Fletcher
Chapter4: Test And Measurement Instruments Used In Residential Wiring
Section: Chapter Questions
Problem 5RQ: List three important rules to follow in the care and maintenance of meters. (Objective 4-14)
Related questions
Question
40gal/min of water is pumped and the energy loss in the discharge line is 13.5 feet and in the suction line it is 2.5 feet. If the steel suction pipe is 2.5” in diameter and the steel discharge pipe is 1.5” in diameter. The pressure in the distribution tank is 30 psi. Determine a) the pressure at the pump outlet b) the power in kW of the pump.
![Tanque
de distribución
ombean 40gal/min de agua y la perdida de energía er
3.5 pies y en la línea de succión es de 2.5 pies. Si la tube
e 2.5" de diámetro y la de descarga de acero es de 1.5
el tanque de distribución es de 30 psi. Determina a) la pr
ba b) la potencia en kW de la bomba. valor 25 pts
5 pies
de 4 pulg
Flujo
+A Bor
212 pies
Bomba
ÉXITOS
3 pies](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F485ec1e4-9878-48c4-9bd8-a9e2a09cfb2f%2F1ae08847-355c-4069-a413-9e54a59090b3%2F7q0enfl_processed.jpeg&w=3840&q=75)
Transcribed Image Text:Tanque
de distribución
ombean 40gal/min de agua y la perdida de energía er
3.5 pies y en la línea de succión es de 2.5 pies. Si la tube
e 2.5" de diámetro y la de descarga de acero es de 1.5
el tanque de distribución es de 30 psi. Determina a) la pr
ba b) la potencia en kW de la bomba. valor 25 pts
5 pies
de 4 pulg
Flujo
+A Bor
212 pies
Bomba
ÉXITOS
3 pies
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 5 steps with 5 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Residential Construction Academy: House Wiring (M…](https://www.bartleby.com/isbn_cover_images/9781337402415/9781337402415_smallCoverImage.gif)
Residential Construction Academy: House Wiring (M…
Civil Engineering
ISBN:
9781337402415
Author:
Gregory W Fletcher
Publisher:
Cengage Learning
![Residential Construction Academy: House Wiring (M…](https://www.bartleby.com/isbn_cover_images/9781337402415/9781337402415_smallCoverImage.gif)
Residential Construction Academy: House Wiring (M…
Civil Engineering
ISBN:
9781337402415
Author:
Gregory W Fletcher
Publisher:
Cengage Learning