3200 HW No. 1 From Given plan and section below, Estimate Quantity of (Footing, Block wall under DPC, Block wall above DPC, Cement Plastering Outside, Gypsum Plastering Inside). Note// Load bearing type structure. All Dimensions Are in mm. Door Dim (1000*2100)mm (RCC Lintels above Doors length 1500mm and depth 250mm. Window Dim (1500*1200)mm (RCC Lintels Above Windows Length 2000mm and depth 250mm. For all Inside Rooms skirting 100mm. 1400 3800 4000 * 700 200 3600 300 -500-3 BED ROOM KITCHEN 3800 3000 DINING 200 LIVING ROOM 400 3800 450 400 200 1400 2200 2000 3000 2300 BATHROOM 3500 3200 3000 1500 BED ROOM 3600 Item Footing Block wall under DPC Block wall above DPC Cement Plastering Outside Gypsum Plastering Inside 200 Unit m3. m3. m3 m2 m2 8400 Quantity 150 THT - 200 400€ 600 650 1000 400

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
HW No.1
From Given plan and section below , Estimate Quantity of (Footing, Block wall under DPC, Block wall above DPC, Cement
Plastering Outside,Gypsum Plastering Inside).
Note// Load bearing type structure.
All Dimensions Are in mm.
Door Dim=(1000*2100)mm (RCC Lintels above Doors length 1500mm and depth 250mm.
Window Dim=(1500*1200)mm (RCC Lintels Above Windows Length 2000mm and depth 250mm.
For all Inside Rooms skirting 100mm.
1400
3800
4000
700 200
150
3600
300 + 500 -
BED ROOM
KITCHEN
1400
2300
3800
200
3000
BATHROOMN
1500
DINING
3500
50- 50
200
LIVING ROOM
BED ROOM
400
400
3600
200
3800
能Co 世
450
009
400
850
200
1000
Item
Unit
Quantity
Footing
Block wall under DPC
Block wall above DPC
Cement Plastering Outside
Gypsum Plastering Inside
m3
m3
m3
m2
m2
008
a a a aa
000s
0008
0007
2200
3200
Transcribed Image Text:HW No.1 From Given plan and section below , Estimate Quantity of (Footing, Block wall under DPC, Block wall above DPC, Cement Plastering Outside,Gypsum Plastering Inside). Note// Load bearing type structure. All Dimensions Are in mm. Door Dim=(1000*2100)mm (RCC Lintels above Doors length 1500mm and depth 250mm. Window Dim=(1500*1200)mm (RCC Lintels Above Windows Length 2000mm and depth 250mm. For all Inside Rooms skirting 100mm. 1400 3800 4000 700 200 150 3600 300 + 500 - BED ROOM KITCHEN 1400 2300 3800 200 3000 BATHROOMN 1500 DINING 3500 50- 50 200 LIVING ROOM BED ROOM 400 400 3600 200 3800 能Co 世 450 009 400 850 200 1000 Item Unit Quantity Footing Block wall under DPC Block wall above DPC Cement Plastering Outside Gypsum Plastering Inside m3 m3 m3 m2 m2 008 a a a aa 000s 0008 0007 2200 3200
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Sizing joists and rafters
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning