2. The dynamic behavior of a pressure sensor/transmitter on a pressurized vessel can be expressed as a first- order transfer function (in deviation variables) that relates the measured pressure P to the actual pressure P: P P 1 40s+1 Both P and P' have units of psi and the time constant is in units of seconds. The vessel has an alarm that sounds when the pressure sensor measures a pressure greater than 150 psi. Normally the vessel operates at 120 psi. However, at 4:15am on Thursday, October 4th, the pressure inside the vessel suddenly increased to 200 psi. At what time did the pressure warning alarm sound?

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question
100%
2. The dynamic behavior of a pressure sensor/transmitter on a pressurized vessel can be expressed as a first-
order transfer function (in deviation variables) that relates the measured pressure P to the actual pressure P:
P
P
1
40s+1
Both P and P' have units of psi and the time constant is in units of seconds.
The vessel has an alarm that sounds when the pressure sensor measures a pressure greater than 150 psi.
Normally the vessel operates at 120 psi. However, at 4:15am on Thursday, October 4th, the pressure inside
the vessel suddenly increased to 200 psi. At what time did the pressure warning alarm sound?
Transcribed Image Text:2. The dynamic behavior of a pressure sensor/transmitter on a pressurized vessel can be expressed as a first- order transfer function (in deviation variables) that relates the measured pressure P to the actual pressure P: P P 1 40s+1 Both P and P' have units of psi and the time constant is in units of seconds. The vessel has an alarm that sounds when the pressure sensor measures a pressure greater than 150 psi. Normally the vessel operates at 120 psi. However, at 4:15am on Thursday, October 4th, the pressure inside the vessel suddenly increased to 200 psi. At what time did the pressure warning alarm sound?
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The