17. Where flexible cords are permitted by the code to be permanently connected, it is permissible to omit for such cords. (a.) switches (b.) receptacles (c.) grounding connections (d.) GFCI protection 18. Listed or labeled equipment shall be installed, used, or both, in accordance with (a.) the fob specified (b.) the plans (c.) the instructions given by the authority having jurisdiction (d.) the instructions included in the listing or labeling 2 19.A grounding electrode connection that is encased in concrete or directly buried shall (a.) be made accessible (b.) be made only by exothermic welding (c.) be a minimum #4 bare (d.) not be required to be accessible 20. Wet niche or no niche lighting fixtures that are supplied by a flexible cord or cable shall all exposed noncurrent carrying metal parts grounded by an insulated copper equipment grounding conductor not smaller than the supply conductors and not smaller than (a.) #16 (c.) # 14 (b.) # 18 (d.) #12| 21. A two pole circuit breaker that may be used for protecting a 3 phase corner grounded delta circuit shall be marked (a.) 1 phase 120/240v (b.) 1 phase – 3 phase (c.) 1 phase/2phase/3phase (d.) 480Y/277v

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
17. Where flexible cords are permitted by the code to be permanently connected, it is
permissible to omit
_for such cords.
(a.) switches (b.) receptacles (c.) grounding connections (d.) GFCI protection
18. Listed or labeled equipment shall be installed, used, or both, in accordance with
(a.) the fob specified (b.) the plans (c.) the instructions given by the authority having
jurisdiction (d.) the instructions included in the listing or labeling 2
19. A grounding electrode connection that is encased in concrete or directly buried
shall
(a.) be made accessible (b.) be made only by exothermic welding (c.) be a minimum #4
bare (d.) not be required to be accessible
20. Wet niche or no niche lighting fixtures that are supplied by a flexible cord or cable
shall all exposed noncurrent carrying metal parts grounded by an insulated
copper equipment grounding conductor not smaller than the supply conductors
and not smaller than
(a.) #16 (c.) # 14 (b.) # 18 (d.) #12|
21. A two pole circuit breaker that may be used for protecting a 3 phase corner
grounded delta circuit shall be marked
(a.) 1 phase 120/240v (b.) 1 phase – 3 phase (c.) 1 phase/2phase/3phase (d.)
480Y/277v
Transcribed Image Text:17. Where flexible cords are permitted by the code to be permanently connected, it is permissible to omit _for such cords. (a.) switches (b.) receptacles (c.) grounding connections (d.) GFCI protection 18. Listed or labeled equipment shall be installed, used, or both, in accordance with (a.) the fob specified (b.) the plans (c.) the instructions given by the authority having jurisdiction (d.) the instructions included in the listing or labeling 2 19. A grounding electrode connection that is encased in concrete or directly buried shall (a.) be made accessible (b.) be made only by exothermic welding (c.) be a minimum #4 bare (d.) not be required to be accessible 20. Wet niche or no niche lighting fixtures that are supplied by a flexible cord or cable shall all exposed noncurrent carrying metal parts grounded by an insulated copper equipment grounding conductor not smaller than the supply conductors and not smaller than (a.) #16 (c.) # 14 (b.) # 18 (d.) #12| 21. A two pole circuit breaker that may be used for protecting a 3 phase corner grounded delta circuit shall be marked (a.) 1 phase 120/240v (b.) 1 phase – 3 phase (c.) 1 phase/2phase/3phase (d.) 480Y/277v
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Methods of Wiring
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,