15. If a type-J thermocouple generates the voltage measurement of 6.541 mV at measured temperature T with reference temperature T =0°C, then the measured temperature T is (a) 122.56 °C (b) 124.27 °c (c) 123.30 °C (d) 121.34 °C

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter1: Heat, Temperature, And Pressure
Section: Chapter Questions
Problem 17RQ: Convert 22C to Fahrenheit.
icon
Related questions
Question
10
15
20
25
30
35
40
45
-250
-8.095
-7.996
-200
-7.890
-7.778
-7.659
-7.534
-7.403
-7.265
-7.123
-6.975
-6.821
-6.663
-150
-6.500
-6.332
6.159
-5.982
-5.801
5.616
-5.426
-5.233
-5.037
4.836
-100
-4.633
-4.425
4.215
-4.002
-3.786
-3.566
-3.344
-3.120
-2.893
-2.663
50
-2431
-2.197
-1.961
-1.722
-1.482
-1.239
-0.995
-0.749
-0.501
-0.251
0.000
0.253
0.507
0.762
1.019
1.277
1.537
1.797
2.059
2322
50
2585
2.850
3.116
3.382
3.650
3.918
4.187
4.456
4.726
4.997
100
5.269
5.541
5.814
6.087
6.360
6.634
6.909
7.184
7.459
7.734
150
8.010
8.286
8.562
8.839
9.115
9.392
9.669
9.947
10.224
10.501
200
10.779
11.056
11.334
11.612
11.889
12.167
12.445
12.722
13.000
13.278
250
13.555
13.833
14.110
14.388
14.665
14.942
15.219
15.496
15.773
16.050
Transcribed Image Text:10 15 20 25 30 35 40 45 -250 -8.095 -7.996 -200 -7.890 -7.778 -7.659 -7.534 -7.403 -7.265 -7.123 -6.975 -6.821 -6.663 -150 -6.500 -6.332 6.159 -5.982 -5.801 5.616 -5.426 -5.233 -5.037 4.836 -100 -4.633 -4.425 4.215 -4.002 -3.786 -3.566 -3.344 -3.120 -2.893 -2.663 50 -2431 -2.197 -1.961 -1.722 -1.482 -1.239 -0.995 -0.749 -0.501 -0.251 0.000 0.253 0.507 0.762 1.019 1.277 1.537 1.797 2.059 2322 50 2585 2.850 3.116 3.382 3.650 3.918 4.187 4.456 4.726 4.997 100 5.269 5.541 5.814 6.087 6.360 6.634 6.909 7.184 7.459 7.734 150 8.010 8.286 8.562 8.839 9.115 9.392 9.669 9.947 10.224 10.501 200 10.779 11.056 11.334 11.612 11.889 12.167 12.445 12.722 13.000 13.278 250 13.555 13.833 14.110 14.388 14.665 14.942 15.219 15.496 15.773 16.050
15. If a type-J thermocouple generates the voltage measurement of 6.541 mV at measured
temperature T with reference temperature T =0°C, then the measured temperature T is
(a) 122.56 °c (b) 124.27 °c (c) 123.30 °c
(d) 121.34 °C
Transcribed Image Text:15. If a type-J thermocouple generates the voltage measurement of 6.541 mV at measured temperature T with reference temperature T =0°C, then the measured temperature T is (a) 122.56 °c (b) 124.27 °c (c) 123.30 °c (d) 121.34 °C
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Instrumentation
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning