1.7 For the system shown in Figure 1.20, the fault at F produces these differing responses at various times: (a) R₁ B₁ and R2 B2 operate; (b) R₁ B₁, R2, R3 B3 and R4 B4 operate; (c) R₁ B1, R2 B2 and R5 B5 operate; (d) R₁ B₁, R5 B5 and R6 B6 operate. Analyze each of these responses for fault F and discuss the possible sequence of events that may have led to these operations. Classify each response as being correct, incorrect, appropriate or inappropriate. Note that 'correct-incorrect' classification refers to relay operation, whereas 'appropriate inappropriate' classification refers to the desirability of that particular response from the point of view of the power system. Also determine whether there was a loss of dependability or a loss of security in each of these cases. R5 B5 R3 B3 R₁ B₁ R2 B2 R4 B4 R6 B6 Figure 1.20 Problem 1.7.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.30P: Reconsider Problem 3.29. If Va,VbandVc are a negative-sequence set, how would the voltage and...
icon
Related questions
Question
Solve this question in detail to understand
1.7 For the system shown in Figure 1.20, the fault at F produces these differing responses at
various times: (a) R₁ B₁ and R2 B2 operate; (b) R₁ B₁, R2, R3 B3 and R4 B4 operate;
(c) R₁ B1, R2 B2 and R5 B5 operate; (d) R₁ B₁, R5 B5 and R6 B6 operate. Analyze each
of these responses for fault F and discuss the possible sequence of events that may have
led to these operations. Classify each response as being correct, incorrect, appropriate or
inappropriate. Note that 'correct-incorrect' classification refers to relay operation, whereas
'appropriate inappropriate' classification refers to the desirability of that particular response
from the point of view of the power system. Also determine whether there was a loss of
dependability or a loss of security in each of these cases.
R5 B5
R3 B3
R₁ B₁
R2 B2
R4 B4
R6 B6
Figure 1.20 Problem 1.7.
Transcribed Image Text:1.7 For the system shown in Figure 1.20, the fault at F produces these differing responses at various times: (a) R₁ B₁ and R2 B2 operate; (b) R₁ B₁, R2, R3 B3 and R4 B4 operate; (c) R₁ B1, R2 B2 and R5 B5 operate; (d) R₁ B₁, R5 B5 and R6 B6 operate. Analyze each of these responses for fault F and discuss the possible sequence of events that may have led to these operations. Classify each response as being correct, incorrect, appropriate or inappropriate. Note that 'correct-incorrect' classification refers to relay operation, whereas 'appropriate inappropriate' classification refers to the desirability of that particular response from the point of view of the power system. Also determine whether there was a loss of dependability or a loss of security in each of these cases. R5 B5 R3 B3 R₁ B₁ R2 B2 R4 B4 R6 B6 Figure 1.20 Problem 1.7.
Expert Solution
steps

Step by step

Solved in 2 steps with 4 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning