1-A d.c. shunt motor is running with certain load. The effect of adding an external resistance field circuit is to a)-reduce the motor speed, b)-increase the motor speed, c)- stop the motor d)- reduce the armature current of the motor 2- The copper loss and iron loss of transformer at half load are 1600 w and 5000w respectively. The copper loss and iron loss at full load will be respectively. a)-(3200 w and 10000w), b)- (6400 w and 5000 w), c)- (6400 w and 10000w), d)-(3200 w and 1250w) 3- The secondary winding of which of the following transformer is always kept close a)-power transformer d)-distribution transformer b)- auto-transformer, c)- current transformer,

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
er C
ai Exa
(B)- Select the correct answer for the alternatives given.
1- A d.c. shunt motor is running with certain load. The effect of adding an external resistance
field circuit is to
a)-reduce the motor speed, b)-increase the motor speed, c)- stop the motor
d)- reduce the armature current of the motor
2- The copper loss and iron loss of transformer at half load are 1600 w and 5000w respectively.
The copper loss and iron loss at full load will be respectively.
a)-(3200 w and 10000w), b)- (6400 w and 5000 w), c)-(6400 w and 10000w),
d)- (3200 w and 1250w)
Way t
3- The secondary winding of which of the following transformer is always kept close
b)- auto-transformer, c)- current transformer,
a)-power transformer
d)-distribution transformer
4- A 6-pole lap wound de shunt generator is supplying 295 A to load. The field current of
generator is 5A. The current parallel path is
a)-300A
245)-145A
b)- 150A,
c)- 50A
باب الثاني
Transcribed Image Text:er C ai Exa (B)- Select the correct answer for the alternatives given. 1- A d.c. shunt motor is running with certain load. The effect of adding an external resistance field circuit is to a)-reduce the motor speed, b)-increase the motor speed, c)- stop the motor d)- reduce the armature current of the motor 2- The copper loss and iron loss of transformer at half load are 1600 w and 5000w respectively. The copper loss and iron loss at full load will be respectively. a)-(3200 w and 10000w), b)- (6400 w and 5000 w), c)-(6400 w and 10000w), d)- (3200 w and 1250w) Way t 3- The secondary winding of which of the following transformer is always kept close b)- auto-transformer, c)- current transformer, a)-power transformer d)-distribution transformer 4- A 6-pole lap wound de shunt generator is supplying 295 A to load. The field current of generator is 5A. The current parallel path is a)-300A 245)-145A b)- 150A, c)- 50A باب الثاني
Expert Solution
steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,