01 A certain load1 with an hourly daily demand as given in table 1 is connected to the same generating station with the load2 that its hourly daily demand is given table 2. The generating station that consists of 3 generating units has a capacity of 72 MW. If the energy price is 0.60 NIS per kWh. The NN are the last two digits (from right) of your registration number (i.e for the student that has a registration number 202132396, NN- 96) Table 1: H 1 2 PI(MW) 2 3 H P(MW) 13 11 Table2: H P2(MW) H P(MW) 13 14 15 1 3 2 3 4 4 13 14 14 12 4 8 4 7 5 9 3 5 15 16 17 18 12 19 24 20 17 16 18 11+(NN/100) 17 19-(NN/199) 23 11:45 18-62 6 10 5 6 7 9 10 12 19 8 12 20 15 7 12 19 22 8 9 12 20 14 14 21 11 9 10 11 12 14 18 21 22 23 12 11 10 11 12 11 14 15 22 23 24 10 8 4 (12 4- Determine the annual load factor for each of the two loads separately. 5- Determine the annual Capacity Factor of the two summed loads together. 6- Determine the diversity factor between the two loads. 7- Suggest the type of each unit in the generating station and its capacity. 16 24 5 23-(NN/100) 22.25 9+(NN/100) 9.75 energy of the summed two loads in a certain 1- Find the price (in NIS) of the consumed year. 2- Sketch the Load/Duration Curve for the 24 hour period for the two loads summed together. 3- Indicate the average load, peak load and base load on the graph for the two summed loads.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
01
A certain load1 with an hourly daily demand as given in table 1 is connected to the same
generating station with the load2 that its hourly daily demand is given table 2. The
generating station that consists of 3 generating units has a capacity of 72 MW. If the
energy price is 0.60 NIS per kWh. The NN are the last two digits (from right) of your
registration number (i.e for the student that has a registration number 202132396, NN =
96)
Table 1:
H
P1(MW) 2 3
H
13 14
P(MW)
13 11
1 2 3
4
15
Table2:
H
P2(MW)
H
P(MW)
1
2
3
4 5
13 14 15
14 12 12
3
4
8
16
11+(NN/100) 17
11:45
5
9
17
16 17 18
19 24 20
6
10
18
19-(NN/199) 23
18.62
4 5 6
79 10
7
12
19
8
12
20
23-(NN/100) 15
22.25
7
12
19
22
8 9
12
20
14
14
21
11 10 8
9 10 11
12 14 18
10 11 12
15
24
4
11 14
22 23
21 22 23
12 11 9+(NN/100)
9.75
4- Determine the annual load factor for each of the two loads separately.
5- Determine the annual Capacity Factor of the two summed loads together.
6- Determine the diversity factor between the two loads.
7- Suggest the type of each unit in the generating station and its capacity.
1- Find the price (in NIS) of the consumed energy of the summed two loads in a certain
year.
2- Sketch the Load/Duration Curve for the 24 hour period for the two loads summed
together.
3- Indicate the average load, peak load and base load on the graph for the two summed
loads.
12
16
24
5
Transcribed Image Text:01 A certain load1 with an hourly daily demand as given in table 1 is connected to the same generating station with the load2 that its hourly daily demand is given table 2. The generating station that consists of 3 generating units has a capacity of 72 MW. If the energy price is 0.60 NIS per kWh. The NN are the last two digits (from right) of your registration number (i.e for the student that has a registration number 202132396, NN = 96) Table 1: H P1(MW) 2 3 H 13 14 P(MW) 13 11 1 2 3 4 15 Table2: H P2(MW) H P(MW) 1 2 3 4 5 13 14 15 14 12 12 3 4 8 16 11+(NN/100) 17 11:45 5 9 17 16 17 18 19 24 20 6 10 18 19-(NN/199) 23 18.62 4 5 6 79 10 7 12 19 8 12 20 23-(NN/100) 15 22.25 7 12 19 22 8 9 12 20 14 14 21 11 10 8 9 10 11 12 14 18 10 11 12 15 24 4 11 14 22 23 21 22 23 12 11 9+(NN/100) 9.75 4- Determine the annual load factor for each of the two loads separately. 5- Determine the annual Capacity Factor of the two summed loads together. 6- Determine the diversity factor between the two loads. 7- Suggest the type of each unit in the generating station and its capacity. 1- Find the price (in NIS) of the consumed energy of the summed two loads in a certain year. 2- Sketch the Load/Duration Curve for the 24 hour period for the two loads summed together. 3- Indicate the average load, peak load and base load on the graph for the two summed loads. 12 16 24 5
Expert Solution
steps

Step by step

Solved in 7 steps with 1 images

Blurred answer
Knowledge Booster
Maximum power transfer theorem
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,