Problem ICA 10-23
Energy Cost
0.106
Brand
Model
Black & Decker
BCE27
Danby Millennium
DAR194BL
Danby Millennium
DAR194W
General Electric
SFR03BAPBB
General Electric
SFR03BAPWW
Haier
ESRB03B
MicroFridge
MHR-2.7E
Silhouette
DAR195BL
Silhouette
DAR259BL
Silhouette
DAR340BL
Sunbeam
SBCR039WE
U-Line
2015R
U-Line
15R
Whirlpool
WAR349BSL
Part a - S
Brand
Model
General Electric
SFR03BAPBB
General Electric
SFR03BAPWW
Many college students have compact refrigerator-freezers in
less than 3.6 cubic feet [cft], according to the American Cou
analysis.
We would like to compute the cost to run each model for a y
“Energy Cost [$/year],” that calculates the annual energy co
Complete the steps below using cell references to given d
To copy/paste a formula across a row or down a column
Excel function is to be used, the directions will specify th
Instead, make a reference to the cell in which the data is
cases, unless otherwise directed, use the earliest appeara
(a)
Sort the first table by energy usage, with the model with
Silhouette
DAR340BL
Whirlpool
WAR349BSL
U-Line
15R
Silhouette
DAR259BL
U-Line
2015R
Danby Millennium
DAR194BL
Danby Millennium
DAR194W
Silhouette
DAR195BL
Black & Decker
BCE27
Haier
ESRB03B
MicroFridge
MHR-2.7E
Sunbeam
SBCR039WE
Which model appears first?
Which model appears first?
Instructions
1Start Excel. 2
3
(b)
Sort by the volume in ascending order and the annual en
Do this part on the ICA 10-23 (b)
worksheet.
(c)
Assume we want to restrict our selection to refrigerators
the models that follow this criterion.
Do this part on the ICA 10-23 (c)
worksheet.
(d)
Assume we want to restrict our selection to refrigerators
kilowatt-hours per year. Use Filter setting in order to display
Do this part on the ICA 10-23 (d)
worksheet.
On the ICA 10-23
worksheet, in cell I10
, by usi
refrigerator. Copy the formula from cell I10
dow
On the ICA 10-23
worksheet, in cells D29-H42
,
Select the cells D29-H42
. Select the Sort & Filte
to sort by Energy Use, sort on Values, and set th
4
5
6
7
8
9
10Save the workbook. Close the workbook and the
On the ICA 10-23
worksheet, in cell F44
, by us
Reference to the appropriate cell in the column On the ICA 10-23 (b)
worksheet, in cell I6
, by u
worksheet. Copy the formula from cell I6
down
On the ICA 10-23 (b)
worksheet, in cells D6-I1
energy cost specified in the column I
. Select the cells D6-I19
. Select the Sort & Filter sort by Volume, sort on Values, and set the order
Then click the Add Level button. At a new level
point)
On the ICA 10-23
worksheet, in cell F48
, by us
Reference to the appropriate cell in the column In the table on the ICA 10-23 (c)
worksheet, use
Select any cell among D5-H5
. Select the Sort &
G5
, in the drop down list select the Number Filt
point)
In the table on the ICA 10-23 (d)
worksheet, use
and only require between 0 and 300 kilowatt-ho
Select any cell among D5-H5
. Select the Sort &
G5
, in the drop down list select the Number Filt
In cell H5
, in the drop down list select the Numb
point)
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
- Access to all documents
- Unlimited textbook solutions
- 24/7 expert homework help
[$ / kWh]
Initial Worksheet
Defrost Type
Energy Use [kWh/yr]
Energy Cost [$ / yr]
Manual
2.7
261
$27.67
Automatic
1.8
302
$32.01
Automatic
1.8
302
$32.01
Automatic
3.2
316
$33.50
Automatic
3.2
316
$33.50
Manual
2.7
261
$27.67
Manual
2.7
260
$27.56
Automatic
1.8
302
$32.01
Automatic
2.5
309
$32.75
Automatic
3.3
316
$33.50
Manual
1.7
252
$26.71
Automatic
3.1
307
$32.54
Automatic
3.5
312
$33.07
Automatic
3.3
316
$33.50
Sorting by Energy Usage
Defrost Type
Energy Use [kWh/yr]
Automatic
3.2
316
Automatic
3.2
316
n their dorm rooms. The data set provided is a partial list of energy-efficient models uncil for an Energy Efficient Economy (www.aceee.org). Complete the following year. Assume that it costs $0.106 per kilowatt-hour [kWh]. Create a new column, ost for each refrigerator.
data or previous calculations. In some cases, a simple cell reference is all you need. n, an absolute cell reference or a mixed cell reference may be preferred. If a specific he use of that function. Do not type in numerical data into a cell or function. s found. Make your computations only in the cells specified in Instructions. In all ance of the data in your formulas.
Volume [ft
3
]
h the highest kilowatt-hour rating listed first. Volume [ft
3
]
Automatic
3.3
316
Automatic
3.3
316
Automatic
3.5
312
Automatic
2.5
309
Automatic
3.1
307
Automatic
1.8
302
Automatic
1.8
302
Automatic
1.8
302
Manual
2.7
261
Manual
2.7
261
Manual
2.7
260
Manual
1.7
252
SFR03BAPBB
SBCR039WE
nergy cost in ascending order.
s that can contain more than 2.0 cubic feet. Use Filter setting in order to display a list of s that can contain more than 2.0 cubic feet and only require between 0 and 300 y a list of the models that follow these criteria.
ing relative and absolute addressing, calculate the annual energy cost for each wn the column to cell I23
. (1 point)
, sort data in descending order of energy usage specified in the column H
. er on the Home tab of the Ribbon, in the drop down list select the Custom Sort. Select he order Largest to Smallest. (1 point)
en exit Excel. Submit the workbook as directed.
sing relative addressing, show the model which appears first in the sorted list of part (a)
. E
. (1 point)
using cell reference, show the annual energy cost from cell I10
on the ICA 10-23
n the column to cell I19
. (1 point)
19
, sort data in ascending order of the volume specified in the column G
and the annual on the Home tab of the Ribbon, in the drop down list select the Custom Sort. Select to r Smallest to Largest. l select to sort by Energy Cost, sort on Values, and set the order Smallest to Largest. (1 sing relative addressing, show the model which appears first in the sorted list of part (b)
. E
on the ICA 10-23 (b)
worksheet. (1 point)
e filter to restrict our selection to refrigerators that can contain more than 2.0 cubic feet.
& Filter on the Home tab of the Ribbon, in the drop down list select the Filter. In cell ters, then select the Greater Than. In the popup window type the required value. (1 e filter to restrict our selection to refrigerators that can contain more than 2.0 cubic feet ours per year.
& Filter on the Home tab of the Ribbon, in the drop down list select the Filter. In cell ters, then select the Greater Than. In the popup window type the required value.
ber Filters, then select the Between. In the popup window type the required values. (1
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
- Access to all documents
- Unlimited textbook solutions
- 24/7 expert homework help
Pa
Brand
Model
Sunbeam
SBCR039WE
Silhouette
DAR195BL
Danby Millennium
DAR194W
Danby Millennium
DAR194BL
Silhouette
DAR259BL
MicroFridge
MHR-2.7E
Black & Decker
BCE27
Haier
ESRB03B
U-Line
2015R
General Electric
SFR03BAPBB
General Electric
SFR03BAPWW
Silhouette
DAR340BL
Whirlpool
WAR349BSL
U-Line
15R
(b)
Sort by the volume in ascending order and the annual en
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
- Access to all documents
- Unlimited textbook solutions
- 24/7 expert homework help
art b - Sorting by Volume then Energy Cost
Defrost Type
Energy Use [kWh/yr]
Energy Cost [$ / yr]
Manual
1.7
252
$27.67
Automatic
1.8
302
$27.56
Automatic
1.8
302
$27.67
Automatic
1.8
302
$33.50
Automatic
2.5
309
$32.75
Manual
2.7
260
$32.01
Manual
2.7
261
$32.01
Manual
2.7
261
$33.50
Automatic
3.1
307
$32.01
Automatic
3.2
316
$26.71
Automatic
3.2
316
$32.54
Automatic
3.3
316
$33.07
Automatic
3.3
316
$33.50
Automatic
3.5
312
$33.50
nergy cost in ascending order. Which model appears first?
Volume [ft
3
]
Brand
Model
Black & Decker
BCE27
General Electric
SFR03BAPBB
General Electric
SFR03BAPWW
Haier
ESRB03B
MicroFridge
MHR-2.7E
Silhouette
DAR259BL
Silhouette
DAR340BL
U-Line
2015R
U-Line
15R
Whirlpool
WAR349BSL
(c)
Assume we want to restrict our selection to refrigerators
the models that follow this criterion.
Part c
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
- Access to all documents
- Unlimited textbook solutions
- 24/7 expert homework help
Defrost Type
Energy Use [kWh/yr]
Manual
2.7
261
Automatic
3.2
316
Automatic
3.2
316
Manual
2.7
261
Manual
2.7
260
Automatic
2.5
309
Automatic
3.3
316
Automatic
3.1
307
Automatic
3.5
312
Automatic
3.3
316
s that can contain more than 2.0 cubic feet. Use Filter setting in order to display a list of c - Volume > 2.0 ft
3
Volume [ft
3
]
Brand
Model
Black & Decker
BCE27
Haier
ESRB03B
MicroFridge
MHR-2.7E
(d)
Assume we want to restrict our selection to refrigerators
kilowatt-hours per year. Use Filter setting in order to display
Part d - Volume > 2.0
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
- Access to all documents
- Unlimited textbook solutions
- 24/7 expert homework help
Defrost Type
Energy Use [kWh/yr]
Manual
2.7
261
Manual
2.7
261
Manual
2.7
260
s that can contain more than 2.0 cubic feet and only require between 0 and 300 y a list of the models that follow these criteria.
0 ft
3
and Energy Use ≤ 300 kWh/yr
Volume [ft