Fe_ICA_10_23_Start

xlsx

School

Clemson University *

*We aren’t endorsed by this school

Course

1410

Subject

Industrial Engineering

Date

Jan 9, 2024

Type

xlsx

Pages

17

Uploaded by CoachWasp3953

Report
Problem ICA 10-23 Energy Cost 0.106 Brand Model Black & Decker BCE27 Danby Millennium DAR194BL Danby Millennium DAR194W General Electric SFR03BAPBB General Electric SFR03BAPWW Haier ESRB03B MicroFridge MHR-2.7E Silhouette DAR195BL Silhouette DAR259BL Silhouette DAR340BL Sunbeam SBCR039WE U-Line 2015R U-Line 15R Whirlpool WAR349BSL Part a - S Brand Model General Electric SFR03BAPBB General Electric SFR03BAPWW Many college students have compact refrigerator-freezers in less than 3.6 cubic feet [cft], according to the American Cou analysis. We would like to compute the cost to run each model for a y “Energy Cost [$/year],” that calculates the annual energy co Complete the steps below using cell references to given d To copy/paste a formula across a row or down a column Excel function is to be used, the directions will specify th Instead, make a reference to the cell in which the data is cases, unless otherwise directed, use the earliest appeara (a) Sort the first table by energy usage, with the model with
Silhouette DAR340BL Whirlpool WAR349BSL U-Line 15R Silhouette DAR259BL U-Line 2015R Danby Millennium DAR194BL Danby Millennium DAR194W Silhouette DAR195BL Black & Decker BCE27 Haier ESRB03B MicroFridge MHR-2.7E Sunbeam SBCR039WE Which model appears first? Which model appears first? Instructions 1Start Excel. 2 3 (b) Sort by the volume in ascending order and the annual en Do this part on the ICA 10-23 (b) worksheet. (c) Assume we want to restrict our selection to refrigerators the models that follow this criterion. Do this part on the ICA 10-23 (c) worksheet. (d) Assume we want to restrict our selection to refrigerators kilowatt-hours per year. Use Filter setting in order to display Do this part on the ICA 10-23 (d) worksheet. On the ICA 10-23 worksheet, in cell I10 , by usi refrigerator. Copy the formula from cell I10 dow On the ICA 10-23 worksheet, in cells D29-H42 , Select the cells D29-H42 . Select the Sort & Filte to sort by Energy Use, sort on Values, and set th
4 5 6 7 8 9 10Save the workbook. Close the workbook and the On the ICA 10-23 worksheet, in cell F44 , by us Reference to the appropriate cell in the column On the ICA 10-23 (b) worksheet, in cell I6 , by u worksheet. Copy the formula from cell I6 down On the ICA 10-23 (b) worksheet, in cells D6-I1 energy cost specified in the column I . Select the cells D6-I19 . Select the Sort & Filter sort by Volume, sort on Values, and set the order Then click the Add Level button. At a new level point) On the ICA 10-23 worksheet, in cell F48 , by us Reference to the appropriate cell in the column In the table on the ICA 10-23 (c) worksheet, use Select any cell among D5-H5 . Select the Sort & G5 , in the drop down list select the Number Filt point) In the table on the ICA 10-23 (d) worksheet, use and only require between 0 and 300 kilowatt-ho Select any cell among D5-H5 . Select the Sort & G5 , in the drop down list select the Number Filt In cell H5 , in the drop down list select the Numb point)
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
[$ / kWh] Initial Worksheet Defrost Type Energy Use [kWh/yr] Energy Cost [$ / yr] Manual 2.7 261 $27.67 Automatic 1.8 302 $32.01 Automatic 1.8 302 $32.01 Automatic 3.2 316 $33.50 Automatic 3.2 316 $33.50 Manual 2.7 261 $27.67 Manual 2.7 260 $27.56 Automatic 1.8 302 $32.01 Automatic 2.5 309 $32.75 Automatic 3.3 316 $33.50 Manual 1.7 252 $26.71 Automatic 3.1 307 $32.54 Automatic 3.5 312 $33.07 Automatic 3.3 316 $33.50 Sorting by Energy Usage Defrost Type Energy Use [kWh/yr] Automatic 3.2 316 Automatic 3.2 316 n their dorm rooms. The data set provided is a partial list of energy-efficient models uncil for an Energy Efficient Economy (www.aceee.org). Complete the following year. Assume that it costs $0.106 per kilowatt-hour [kWh]. Create a new column, ost for each refrigerator. data or previous calculations. In some cases, a simple cell reference is all you need. n, an absolute cell reference or a mixed cell reference may be preferred. If a specific he use of that function. Do not type in numerical data into a cell or function. s found. Make your computations only in the cells specified in Instructions. In all ance of the data in your formulas. Volume [ft 3 ] h the highest kilowatt-hour rating listed first. Volume [ft 3 ]
Automatic 3.3 316 Automatic 3.3 316 Automatic 3.5 312 Automatic 2.5 309 Automatic 3.1 307 Automatic 1.8 302 Automatic 1.8 302 Automatic 1.8 302 Manual 2.7 261 Manual 2.7 261 Manual 2.7 260 Manual 1.7 252 SFR03BAPBB SBCR039WE nergy cost in ascending order. s that can contain more than 2.0 cubic feet. Use Filter setting in order to display a list of s that can contain more than 2.0 cubic feet and only require between 0 and 300 y a list of the models that follow these criteria. ing relative and absolute addressing, calculate the annual energy cost for each wn the column to cell I23 . (1 point) , sort data in descending order of energy usage specified in the column H . er on the Home tab of the Ribbon, in the drop down list select the Custom Sort. Select he order Largest to Smallest. (1 point)
en exit Excel. Submit the workbook as directed. sing relative addressing, show the model which appears first in the sorted list of part (a) . E . (1 point) using cell reference, show the annual energy cost from cell I10 on the ICA 10-23 n the column to cell I19 . (1 point) 19 , sort data in ascending order of the volume specified in the column G and the annual on the Home tab of the Ribbon, in the drop down list select the Custom Sort. Select to r Smallest to Largest. l select to sort by Energy Cost, sort on Values, and set the order Smallest to Largest. (1 sing relative addressing, show the model which appears first in the sorted list of part (b) . E on the ICA 10-23 (b) worksheet. (1 point) e filter to restrict our selection to refrigerators that can contain more than 2.0 cubic feet. & Filter on the Home tab of the Ribbon, in the drop down list select the Filter. In cell ters, then select the Greater Than. In the popup window type the required value. (1 e filter to restrict our selection to refrigerators that can contain more than 2.0 cubic feet ours per year. & Filter on the Home tab of the Ribbon, in the drop down list select the Filter. In cell ters, then select the Greater Than. In the popup window type the required value. ber Filters, then select the Between. In the popup window type the required values. (1
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
Pa Brand Model Sunbeam SBCR039WE Silhouette DAR195BL Danby Millennium DAR194W Danby Millennium DAR194BL Silhouette DAR259BL MicroFridge MHR-2.7E Black & Decker BCE27 Haier ESRB03B U-Line 2015R General Electric SFR03BAPBB General Electric SFR03BAPWW Silhouette DAR340BL Whirlpool WAR349BSL U-Line 15R (b) Sort by the volume in ascending order and the annual en
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
art b - Sorting by Volume then Energy Cost Defrost Type Energy Use [kWh/yr] Energy Cost [$ / yr] Manual 1.7 252 $27.67 Automatic 1.8 302 $27.56 Automatic 1.8 302 $27.67 Automatic 1.8 302 $33.50 Automatic 2.5 309 $32.75 Manual 2.7 260 $32.01 Manual 2.7 261 $32.01 Manual 2.7 261 $33.50 Automatic 3.1 307 $32.01 Automatic 3.2 316 $26.71 Automatic 3.2 316 $32.54 Automatic 3.3 316 $33.07 Automatic 3.3 316 $33.50 Automatic 3.5 312 $33.50 nergy cost in ascending order. Which model appears first? Volume [ft 3 ]
Brand Model Black & Decker BCE27 General Electric SFR03BAPBB General Electric SFR03BAPWW Haier ESRB03B MicroFridge MHR-2.7E Silhouette DAR259BL Silhouette DAR340BL U-Line 2015R U-Line 15R Whirlpool WAR349BSL (c) Assume we want to restrict our selection to refrigerators the models that follow this criterion. Part c
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
Defrost Type Energy Use [kWh/yr] Manual 2.7 261 Automatic 3.2 316 Automatic 3.2 316 Manual 2.7 261 Manual 2.7 260 Automatic 2.5 309 Automatic 3.3 316 Automatic 3.1 307 Automatic 3.5 312 Automatic 3.3 316 s that can contain more than 2.0 cubic feet. Use Filter setting in order to display a list of c - Volume > 2.0 ft 3 Volume [ft 3 ]
Brand Model Black & Decker BCE27 Haier ESRB03B MicroFridge MHR-2.7E (d) Assume we want to restrict our selection to refrigerators kilowatt-hours per year. Use Filter setting in order to display Part d - Volume > 2.0
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help
Defrost Type Energy Use [kWh/yr] Manual 2.7 261 Manual 2.7 261 Manual 2.7 260 s that can contain more than 2.0 cubic feet and only require between 0 and 300 y a list of the models that follow these criteria. 0 ft 3 and Energy Use ≤ 300 kWh/yr Volume [ft 3 ]