Question
error_outline
This textbook solution is under construction.
Students have asked these similar questions
A refrigerator in a meat warehouse must keep a low temperature of -20°C and the outside temperature is 25°C. Ammonia is used as the refrigerant which must remove 10 kW from the cold space. Compute for the flow rate of the ammonia needed assuming a standard vapor compression refrigeration cycle with a condenser at 25°C. Find the enthalpy of the stream exiting the evaporator, condenser, and throttling (expansion) valve.
Solve fast..
Heat is transferred to a heat engine from a fumace at a rate of 120KW. If the rate of waste heat rejection to a nearby river is 50000W. Find the net Power output and the thermal efficiency for this heat engine.
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A refrigerator cycle uses refrigerant R-134a and operates between a low-side pressure of 1.5 Bar and high side of 10 Bar. The power input to the compressor 1.88 Kw. find the refrigerant mass flow rate, condensing heat load, and COP of this machinearrow_forwardI need answer in handwrittenarrow_forwardQ A Solar water heating System connected to 250 kg water- energy storage tank has UA equal 12 2 and is located in aroom that is at a constant temperature 20c where the load is 20 MJ, the final temp storage tank is not exceeding to 98e, the intial temp. is use Find the required energy delivered to storage tank take ( st=1) 2. Calculate the number of collectors if the efficiency of the collector is yo% the dimensions of the Collector is (100 cm * 75cm) and the total globle radiation is 6.6 Kwh/m² .arrow_forward
- Q.7 The COP of the heat pump is found to be 5.62, and the heat pump operates with the source at 25°C, while the heat absorbed is 2.12 kW. What is the amount of heat rejected ?arrow_forwardA refrigeration system operates an ideal vapor compression using R-143a with an evaporator temperature of-30°C and the condenser exist temperature of 50°C and requires 75 KW motor to drive the compression. What is the cooling capacity of the refrigerator in KW? And find COP.arrow_forwardA refrigerator uses a power input of 2 KW to cool a 5 C° space with the high temperature in the cycle as 50 c°. The heat removed from the cycle Q, is pushed to the ambient in a heat exchanger its heat transfer area is 24 m. Find the heat transfer coefficient required in W/m K. (Assume the cycle works on Carnot cycle) heat exchanger T amby ´REF) | T2= 5 C° 35 C TH= 50 carrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
How Shell and Tube Heat Exchangers Work (Engineering); Author: saVRee;https://www.youtube.com/watch?v=OyQ3SaU4KKU;License: Standard Youtube License